Composite

Part:BBa_K4115039

Designed by: Kaijun Wang   Group: iGEM22_ShanghaiTech_China   (2022-09-30)


J23101-B0034-luxR-B0015-Lux pR-B0034-sfGFP-B0015

J23101-B0034-luxR-B0015-Lux pR-B0034-sfGFP-B0015
Function Gene regulator
Use in E. coli
RFC standard RFC 10, RFC 10 compatible
Backbone pBBR1, pUC57
Submitted by ShanghaiTech_China

This composite part is used to detect the response of LuxR (BBa_C0062) to AHL signaling molecules [1]. When LuxR receives the signal of AHL, it can regulate the downstream Lux pR (BBa_R0062) to make superfolder GFP (BBa_K4115000) express.
This part is togther used with LuxI (BBa_C0161), an AHL(3OC6 HSL here) sender. We have first transformed this composite part into the plasmid backbone PUC57 to do some validation experiments. Thus, we can later transform the plasmid into the A.caulinodans ORS571 by using the plasmid backbone pBBR1 to construct communications and regulations system between E. coli and S.elongatus HL7942 through quorum sensing signals.

Figure 1: Lux QS system path.















Proof of function

We encapsulated E. coli with this composite part and E. coli with LuxI into alginate gel beads. The E. coli with LuxI secreted the 3OC6 HSL signal molecule, and the E. coli with LuxR received the signal and regulate the expression of downstream sfGFP, making it express. So we can detect green fluorescence in the latter E. coli under the irradiation of ultraviolet light and gain Figure 2.

Figure 2: sfGFP is expressed under the regulation of LuxR between E. coli in a single gel bead. Two parallel groups are given and the above two are control groups.























We put the gel beads of the experimental group and the control group on a confocal microscope for imaging observation, and found that there was a significant difference in fluorescence intensity between the two groups (Figure 3-4). Thus, the Lux system was proved to be functional between E. coli.

Figure 3: 10X Confocal image of the control group's gel beads.
Figure 4: 10X Confocal image of the experimental group's gel beads.


























Quantitative analysis

Experiment approach

1. Dilute the E. coli DH5α cultures transformed with BBa_K4115039 that were stored at 4℃ 1:100 into 3ml LB medium and grow at 37℃ with shaking at 220rpm overnight.
2. Dilute the overnight cultures 1:100 into 3ml LB medium and grow at 37℃ with shaking at 220rpm for 3h. Measure their OD600 with Nanodrop One.
3. Dilute the culture with LB medium to OD600~0.1. Add 600ul diluted cultures to each 1.5ml tube. Add 0.6 ul autoinducer solution to each tube. The final concentrations of the autoinducer range from 10-4 to 10-14 M.
4. After culturing at 37℃ with shaking at 220rpm for three hours, add 200ul to each well of the black bottom 96-well plate for fluorescence intensity testing. Use an excitation wavelength of 485nm and an emission wavelength of 535nm.
5. Add 200ul to each well of the transparent 96-well plate for OD600 measurement.

Results

We process the raw data by dividing the fluorescence intensity by the OD600 and get Figure 5. Thus, we can conclude the response intensity of LuxR to 3O6C HSL at different concentrations.
The result is similar to the one in the paper [1].

Figure 5: Different 3O6C HSL concentrations are inputed to test LuxR response intensity.






















2023-HZAU Characterization

50μL E.coli BL21(DE3) with 50μL luxR (BBa_K4115039) + 50μL blank E.coli BL21(DE3) and 50μL luxR (BBa_K4115039) + 50μL E.coli BL21(DE3) with luxI (BBa_C0161) was respectively mixed with 5mL LB medium. Then they were cultured in microplate reader 37°C, 220 rpm for 8 hours and detected OD600, fluorescence intensity (458 nm excitation light, 489 nm emission light) every 10 minutes. What?


Figure 6. Fluorescence intensity in different value of OD600.

Sequence and Features BBa_K4115039 Sequence And Features Not understood

References

[1] Kylilis, N., Tuza, Z.A., Stan, GB. et al. Tools for engineering coordinated system behaviour in synthetic microbial consortia. Nat Commun 9, 2677 (2018). https://doi.org/10.1038/s41467-018-05046-2


[edit]
Categories
Parameters
None