Difference between revisions of "Part:BBa F2620:Stability/Mutant"

Line 6: Line 6:
 
<div style="padding: 00px; width: 680px; border: 0px solid #000000;">
 
<div style="padding: 00px; width: 680px; border: 0px solid #000000;">
 
==Description==
 
==Description==
Repeating the [[Part:BBa F2620:Stability|stability experiment]] indicated that device failure occurred after a fixed number of doublings.  This non-intuitive result could be explained if there was pre-existing genetic variation in the long term stock of the device.  Since the experiment was started each time from a single colony, that pre-existing genetic variation must be intra-cellular rather than extracellularT9002 was carried on a multi-copy plasmid (<partinfo>pSB3k3</partinfo>) and it is conceivable that a small fraction of those were mutants in each cell.     
+
Device failure was caused by the accumulation of a mutant that had a deletion between two 143bp homologous regions in BBa_T9002.  Cells harboring the truncated device grew faster than cells harboring the full device under high input conditions, presumably because the mutant did not produce GFP and hence had a reduced demand.  Repeating the [[Part:BBa F2620:Stability|stability experiment]] indicated that device failure occurred after a fixed number of doublings.  This was a non-intuitive result as we expected that a mutation that conferred a selective advantage would occur at a random time and hence that the time at which that mutant would take over the population would be random. The consistency in device failure time could be explained if there was pre-existing genetic variation in the long-term stock of the device.  Since the experiment was started each time from a single colony, that pre-existing genetic variation must be intra-cellular rather than extra-cellularBBa_T9002 was carried on a multi-copy plasmid, <partinfo>pSB3k3</partinfo> (~60 per cell), and it is conceivable that a small fraction of those were mutants in each cell of the long-term stock.     
  
 
==Analysis==
 
==Analysis==
Line 14: Line 14:
 
'''Lanes 10, 18, 20, 22:'''Colony PCR of 4 colonies from a freshly streaked plate of MG1655 containing the mutant T9002 on pSB3k3]]
 
'''Lanes 10, 18, 20, 22:'''Colony PCR of 4 colonies from a freshly streaked plate of MG1655 containing the mutant T9002 on pSB3k3]]
 
[[Image:T9002PCRfromextracts2.png|thumb|right|300px|]]
 
[[Image:T9002PCRfromextracts2.png|thumb|right|300px|]]
Analysis of sequence trace data using purified T9002 DNA did not indicate the presence of the mutant plasmid.  We chose to test for the presence of the mutant plasmid in the long term stock by pcr analysis.   
+
We first analyzed the sequence trace data of purified BBa_T9002 DNA but could not find evidence of the presence of the mutant plasmid.  We next tested for the presence of the mutant plasmid in the long-term stock by PCR analysis.   
  
In an initial step, we performed a colony PCR on 4 colonies from a freshly streaked plate of T9002.  The thermocycling conditions used were - 95C for 1 min, 55C for 30 s, 72C for 70 s repeated 34 times.  The PCR product was analyzed via electrophoresis (8 V/cm 1% agarose in TAE) and the resulting gel is shown in Figure 1.  The strongest band for the four colonies was at the expected length for T9002 (lanes 2, 4, 6, 8).  Multiple shorter bands can also be seen in those lanes, including one band that is the expected length of the T9002 mutant (1300bp).  Both <partinfo>T9002</partinfo> and the mutant can be digested with HindIII ([http://neb.com NEB]) however digestion of the PCR product with HindIII (3 hrs, 37C) did not conclusively show a shift in the band that might correspond to the mutant device (lanes 3, 5, 7 9).   
+
We performed a colony PCR on 4 colonies from a freshly streaked plate of MG1655 harboring BBa_T9002.  The thermocycling conditions used were - 95C for 1 min, 55C for 30 s, 72C for 70 s repeated 34 times.  The PCR product was analyzed via electrophoresis (8 V/cm 1% agarose in TAE) and the resulting gel is shown in Figure 1.  The strongest band for the four colonies was at the expected length for T9002 (lanes 2, 4, 6, 8).  Multiple shorter bands can also be seen in those lanes, including one band that is the expected length of the T9002 mutant (1300bp).  Both <partinfo>T9002</partinfo> and the mutant can be digested with HindIII ([http://neb.com NEB]) however digestion of the PCR product with HindIII (3 hrs, 37C) did not conclusively show a shift in the band that might correspond to the mutant device (lanes 3, 5, 7 9).   
  
 
We purified the DNA from the potential mutant bands in lanes 2 and 8 using a Qiagen gel extraction kit (Qiagen).  We performed PCR on the purified DNA using the same thermocycling conditions described above and analyzed the PCR products by electrophoresis (Figure 2).  On the bottom row, lanes 2, 4, and 6 are the results of PCR reactions using different amounts of template DNA, 15&mu;l of the 50&mu;l PCR reaction were loaded into the gel.  A faint band can be seen at the expected length for the mutant device at 1300bp along with two brighter bands at 600bp and 300bp.  30&mu;l of the PCR products were digested with HindIII and loaded into the gel (lanes 3, 5, and 7).  The 1200bp band is very faint in these lanes and a band exists just above 1000bp at at 27bp which are the expected length of the fragments of the mutant device PCR product digested with HindIII.   
 
We purified the DNA from the potential mutant bands in lanes 2 and 8 using a Qiagen gel extraction kit (Qiagen).  We performed PCR on the purified DNA using the same thermocycling conditions described above and analyzed the PCR products by electrophoresis (Figure 2).  On the bottom row, lanes 2, 4, and 6 are the results of PCR reactions using different amounts of template DNA, 15&mu;l of the 50&mu;l PCR reaction were loaded into the gel.  A faint band can be seen at the expected length for the mutant device at 1300bp along with two brighter bands at 600bp and 300bp.  30&mu;l of the PCR products were digested with HindIII and loaded into the gel (lanes 3, 5, and 7).  The 1200bp band is very faint in these lanes and a band exists just above 1000bp at at 27bp which are the expected length of the fragments of the mutant device PCR product digested with HindIII.   
  
 
This analysis adds weight to the hyposthesis that the plamid bearing the mutant device is present, in low numbers in the long-term stock of the device.
 
This analysis adds weight to the hyposthesis that the plamid bearing the mutant device is present, in low numbers in the long-term stock of the device.

Revision as of 19:07, 14 October 2006

Input: 3OC6HSL
Output: PoPS

tetR
R0040
LuxR
I0462
lux pR
R0062
BBa F2620Icon.png

Part Main Page        Transfer Function        Specificity        Response time        Stability        Add Data       


Description

Device failure was caused by the accumulation of a mutant that had a deletion between two 143bp homologous regions in BBa_T9002. Cells harboring the truncated device grew faster than cells harboring the full device under high input conditions, presumably because the mutant did not produce GFP and hence had a reduced demand. Repeating the stability experiment indicated that device failure occurred after a fixed number of doublings. This was a non-intuitive result as we expected that a mutation that conferred a selective advantage would occur at a random time and hence that the time at which that mutant would take over the population would be random. The consistency in device failure time could be explained if there was pre-existing genetic variation in the long-term stock of the device. Since the experiment was started each time from a single colony, that pre-existing genetic variation must be intra-cellular rather than extra-cellular. BBa_T9002 was carried on a multi-copy plasmid, pSB3K3 (~60 per cell), and it is conceivable that a small fraction of those were mutants in each cell of the long-term stock.

Analysis

Lane 1: 2-log ladder (NEB)
Lanes 2, 4, 6, 8:Colony PCR of 4 colonies from a freshly streaked plate of T9002 on pSB3k3 in MG1655
Lanes 3, 5, 7, 9:HindIII (NEB) digest of the PCR product in lanes 2, 4, 6, 8.
Lanes 10, 18, 20, 22:Colony PCR of 4 colonies from a freshly streaked plate of MG1655 containing the mutant T9002 on pSB3k3
T9002PCRfromextracts2.png

We first analyzed the sequence trace data of purified BBa_T9002 DNA but could not find evidence of the presence of the mutant plasmid. We next tested for the presence of the mutant plasmid in the long-term stock by PCR analysis.

We performed a colony PCR on 4 colonies from a freshly streaked plate of MG1655 harboring BBa_T9002. The thermocycling conditions used were - 95C for 1 min, 55C for 30 s, 72C for 70 s repeated 34 times. The PCR product was analyzed via electrophoresis (8 V/cm 1% agarose in TAE) and the resulting gel is shown in Figure 1. The strongest band for the four colonies was at the expected length for T9002 (lanes 2, 4, 6, 8). Multiple shorter bands can also be seen in those lanes, including one band that is the expected length of the T9002 mutant (1300bp). Both BBa_T9002 and the mutant can be digested with HindIII ([http://neb.com NEB]) however digestion of the PCR product with HindIII (3 hrs, 37C) did not conclusively show a shift in the band that might correspond to the mutant device (lanes 3, 5, 7 9).

We purified the DNA from the potential mutant bands in lanes 2 and 8 using a Qiagen gel extraction kit (Qiagen). We performed PCR on the purified DNA using the same thermocycling conditions described above and analyzed the PCR products by electrophoresis (Figure 2). On the bottom row, lanes 2, 4, and 6 are the results of PCR reactions using different amounts of template DNA, 15μl of the 50μl PCR reaction were loaded into the gel. A faint band can be seen at the expected length for the mutant device at 1300bp along with two brighter bands at 600bp and 300bp. 30μl of the PCR products were digested with HindIII and loaded into the gel (lanes 3, 5, and 7). The 1200bp band is very faint in these lanes and a band exists just above 1000bp at at 27bp which are the expected length of the fragments of the mutant device PCR product digested with HindIII.

This analysis adds weight to the hyposthesis that the plamid bearing the mutant device is present, in low numbers in the long-term stock of the device.