Chassis/Cell-Free Systems/Commercial E.coli S30/Peak Time

Revision as of 14:15, 21 October 2007 by Cheuk Ka Tong (Talk | contribs) (Peak Time)

Commercial E. coli S30

Cell-Free Systems Chassis description Optimum temperature Peak time Product stability Expression capacity Expression lifespan

Peak Time

Graph 2. Graph of rate of GFP synthesis (mol per min) against time (minutes) at 4oC (dark blue), 15oC (pink), 20oC (yellow) and 30oC (light blue). The simple constitutive gene expression device BBa_I13522 has been used. Each of the four coloured lines show average measurements based on three replicates of the experiment. This graph is derived from Graph 1, with addition data from our GFP calibration curve. Please visit our OpenWetWare for the detailed protocol and raw data of the experiment.

Discussion
The peak time of the expression of GFP in the Commercial E. coli S30 chassis occurred at about 90 minutes after the start of the reaction. This value was consistent at the different operating temperatures investigated.