Difference between revisions of "Part:BBa E0840"
Line 54: | Line 54: | ||
<figure> | <figure> | ||
− | <center><img src="https://static.igem.org/mediawiki/2016/e/e2/T--TU_Delft--blablagahkd.png" alt="fluorophores" width=" | + | <center><img src="https://static.igem.org/mediawiki/2016/e/e2/T--TU_Delft--blablagahkd.png" alt="fluorophores" width="80%"> |
<figcaption><b>Figure 1.</b> GFP. Kinetic measurement of fluorescence intensity at | <figcaption><b>Figure 1.</b> GFP. Kinetic measurement of fluorescence intensity at | ||
522 nm and optical density at 600 nm, while shaking at 37°C. Above | 522 nm and optical density at 600 nm, while shaking at 37°C. Above |
Revision as of 20:54, 18 October 2016
GFP generator
BBa_E0840 takes as input a transcriptional signal (PoPS) and produce as output the fluorescent protein GFP.
Usage and Biology
- See BBa_E0040 for additional details.
- BBa_E0840 is often used to quantify the behavior of transcriptional control devices such as promoters.
- BBa_E0840 has a strong ribosome binding site.
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000INCOMPATIBLE WITH RFC[1000]Illegal BsaI.rc site found at 665
Improvements
Group: TU Delft 2016
Author: Lycka Kamoen and María Vázquez Vitali
Summary: Part BBa_E0840 does not contain any promoter, thus it can only be used if cloned downstream of one. It is also for this reason that this part (BBa_E0840) did not have any characterization. We have improved this BioBrick in 2 different ways: on the one hand, we provided 5 ready-to-go expression devices for green fluorescence (with promoters of different strengths), which can be used by future teams; on the other hand, this has allowed us to provide characterization for this uncharacterized GFP part. Using PCR primers, we added either of the constitutive promoters BBa_J23100, BBa_J23108, BBa_J23105, BBa_J23117 and BBa_J23113 to this part, to create five new biobrick devices. All of these biobricks were characterized by measuring their spectrum and growth cycle.New parts: BBa_K1890020, BBa_K1890021, BBa_K1890022, BBa_K1890023, BBa_K1890024.
Characterization
The emission spectra of all members of the colleection were measured in the same plate reader in parallel experiments and the results were normalized by dividing by the OD600 (Figure 1).
The emission peak is found at 511nm, which is in accordance with what was documented by Cormack et al. [1]. In figure 1, the difference of fluorescence intensity between each individual strains is, as expected, related to the promoters strengths.
For comparison, all fluorophore spectra were also recorded in a dilution more suited for their emission intensity and normalized by maximum intensity of each construct (Figure 2). From this figure we can conclude that all GFP biobricks function properly and that the emission peak is consistent in at all expression stregths.
Figure 3 shows the 24 hour measurement of optical density and fluorescence intensity. The final OD600 is approximately equal for all different strains, suggesting that the level of constitutive expression was not influencing the growth. Furthermore, fluorescence intensity drops after the exponential growth phase, suggesting that GFP is being broken down by proteases as a response to nutrient limitation. After this event, growth continues at a slower pace, while GFP activity keeps decreasing. All in all, constitutive expression of GFP does not seem to have a detrimental effect on cell growth during exponential phase.