Part:BBa_K3503004
CBD-SR-His
This is a composite part designed to improve the fire retardancy with cellulose-binding domain K1321014. The protein sequence in this part is based on the K1608000 sequence from MingDao 2015
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21INCOMPATIBLE WITH RFC[21]Illegal BglII site found at 146
Illegal BglII site found at 263
Illegal BglII site found at 332
Illegal BamHI site found at 107 - 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]
Sequencing and sequence alignment of K3503004
To future confirm that our constructs have the correct sequence, we send our clones (with positive PCR results) out to sequencing.
The sequencing results show that we have successfully assembled target genes K3503004 to the vector (pET-11a).
Successful expression of K3503004
In order to validate the protein expression of K1608000, K3503006 and K3503004, we performed SDS-PAGE (coomassie blue staining) and Western blot analysis. To make K3503001, K3503007 and K3503008 easily detectable via Western Blot, we designed our constructs to include a “His tag” which is targeted by a commercially available antibody. With the SDS-PAGE and western blot (anti-his for his-tagged protein), we found successful expression of K1608000, K3503006 and K3503004
Before performing the SDS-PAGE, we grew up our engineered E. coli cells containing a plasmid with K1608000, K3503006 and K3503004 under control of the T7 promoter. Cells were induced with0.1mM IPTG until either OD0.4 (wavelength: 600nm) at 30°C. After expression, cells were then lysed according to our protein extraction protocol, and supernatant and pellet were collected for the SDS-PAGE.
(a) Coomassie blue staining
(b) Western Blot
- Lane1: Bio rad protein dual color ladder;
- Lane2: pet11a
- Lane3: SR(K1608000)
- Lane4:SR(K1608000) with 1mM IPTG induction
- Lane5: K3503006(mfp5-SR)
- Lane6: K3503006(mfp5-SR) with 1mM IPTG induction
- Lane7: K3503004(CBD-SR)
- Lane8: K3503004(CBD-SR) with 1mM IPTG induction
Fire retardant test of K3503004
The test subject was in the size of bed sheet in 300*130mm and the average Moisture content% is 13.55%-14.37%. As demonstrated on Fig 3, all of our engineered flame retardant displayed an improvement compared with the water control.
As demonstrated in Fig 4, all of our engineered K3503001, K3503007 and K3507008 flame retardants displayed an improvement compared with the water control.