Measurement
InATst

Part:BBa_J05503

Designed by: ETH Zurich iGEM Team 2005   Group: iGEM2005   (2005-09-22)


Sensing Device A (cI) TESTER (Pr+GFP+Prm+RFP)

A debug version of the event sensing and processing system for the iGEM2005 ETH "Counter" project: its purpose is to regulate cI production dependent on an external event. It works somehow like an inverter:

STATE 1: when IPTG is absent, the constitutively produced lacI protein will block the lacI+pL promoter so that no cI is produced. Thus downstream the Pr promoter will be constitutively active, producing GFP (green fluorescence), while Prm+ will have low or no activity (no/low RFP - red fluorescence).

STATE 2: when IPTG is present, it will remove the lacI protein from the lacI+pL promoter and cI is produced. Thus downstream the Pr promoter will be repressed (no GFP, i.e. no green fluorescence) by cI, while Prm+ will be activated, producing RFP (red fluorescence).

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal BglII site found at 1227
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal AgeI site found at 3982
    Illegal AgeI site found at 4094
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal BsaI.rc site found at 3098


[edit]
Categories
//classic/measurement/uncategorized
Parameters
None