Part:BBa_K5107006
T7-HRE5-dB-T
T7-HRE5-dB-T is a construct used by the cell free biosensor.The HRE5 is recognised by the steroid androgen, progenesterone and glycocorticoid hormone receptor. Then in vitro transcription of the dimeric broccoli is taken place if the hormone is present or not in the cell free solution
Usage and Biology
For the structure of the biosensor, we took inspiration from the ROSALIND cell-free biosensor[1], modifying their design to match our goals. We kept the general idea of having a Transcription Factor (TF) altering the activity of a RNA polymerase, and the output signal as a consequence. We tailored the ROSALIND concept by selecting specific custom transcription factors (TFs) as receptors and designing unique operator sequences to serve as responsive elements. The exact parts are described here:
Cell free biosensor
Assemply
We used USER cloning to assemble the T7-HRE5-dB-T and T7-ERE5-dB-T. For the design of the assembly we used the AMUSER tool https://services.healthtech.dtu.dk/services/AMUSER-1.0/. The USER assembly consists of 2 steps - PCR and the USER reaction.
- First, we ran PCR reactions using primers from the AMUSER tool for the following parts:
- pUC19-T7-3WJdB-T(Addgene)
- HRE5 (pRR-PR-5Z template)
- ERE5 (pRR-ERalpha-5Z template)
Each of the primers used to amplify a given response element part (HRE5, ERE5) was equipped with a specific USER overhang, complementary to the overhangs produced in plasmid backbone (pUC19-T7-3WJdB-T(Addgene). For the PCRs, a Phusion U Hot Start polymerase that tolerates uracil bases was used. As a result, we obtained PCR products ready for USER cloning procedure.
- USER cloning
USER cloning is a uracil-based excision technique that utilizes USER (Uracil-Specific Excision Reagent) enzyme to create specific 3’-overhangs on a DNA template. PCR products with double-strand USER overhangs (each containing uracil base) are subdued to the activity of USER and DpnI enzymes, resulting in an assembly of complementary overhangs and ligation of the templates.In our case, each of the responsive elements (HRE5, ERE5) was cloned into a backbone plasmid pUC19-T7-3WJdB-T(Addgene). As a result, we produced two plasmids:
- pUC19-T7HRE5-3WJdB-T (pUC19_HRE5)
- pUC19-T7_ERE5-3WJdB-T (pUC19_ERE5)
- Validation
Each plasmid was transformed into and amplified in E. coli strain DH5-α. The final ROSALIND templates (T7HRE5-3WJdB-T and T7_ERE5-3WJdB-T) were obtained by PCR of the target sequences containing only the DNA parts necessary for Cell-Free Transcription System.Here it is shown only the gel electrophoresis of the T7-HRE5-dB-T.
Test and Optimization
To test the created parts, we performed two iterations. Firstly, we tested and optimized the fluorescence output without the presence of any receptor or ligand (Test & Learn I), to ensure that the design at its basic level works properly. Secondly, we proceeded by testing the biosensor on its whole with the receptor and the ligands (Test & Learn II).
1. Wavelength and Plate reader setting
- Rationale: As the signal for the first experiments was erratic and sometimes incoherent, we tried to improve the reading settings.
- Result:Higher fluorescence output was yielded by:
Using the wavelength couple 488/530 nm. Reading from the top (instead from the bottom)
- Rationale: Optimize the reaction to increase the signal
Initially, for the first transcription test, we used a custom In Vitro Transcription (IVT) buffer recommended from the ROSALIND protocol (where we took the inspiration for the cell-free system). However, we didn’t get any fluorescence emission by using that custom buffer.
- Result: The commercial In Vitro Transcription (IVT) buffer was better than the custom made.
When using the commercial buffer, we could see a much higher output signal. The custom buffer clearly is not ideal for the cell-free transcription, while the commercial buffer seems to work much better. A possible explanation for this, is the ionic concentration, which is much higher in the custom buffer (especially NaCl). Either the indicated concentrations were wrong (we in fact acknowledge a mistake in the ROSALIND protocol, as the indicated concentration of the NaCl ion was too high) or we made a mistake in the process of preparing it.
3. DNA concentration
- Rationale: Increase the sensitivity of the biosensor, enlarge the limits of detection, and reduce the cost of testing.
Reducing the amount of DNA enhances both sensitivity and the limit of detection, which are critical factors for our stakeholders. This reduction will ultimately lower the detection threshold, allowing even trace amounts of EDCs in the tested water to produce measurable inhibition. Additionally, it enables us to minimize the use of the receptor, the most expensive component of the biosensor system.
- Results: A concentration of 10 nM of DNA was sufficient to yield a substantial signal and the best one to perform the next experiments, also according to the Modeling analysis.
Sequence and Features
- 10INCOMPATIBLE WITH RFC[10]Illegal XbaI site found at 72
Illegal PstI site found at 60 - 12INCOMPATIBLE WITH RFC[12]Illegal PstI site found at 60
- 21COMPATIBLE WITH RFC[21]
- 23INCOMPATIBLE WITH RFC[23]Illegal XbaI site found at 72
Illegal PstI site found at 60 - 25INCOMPATIBLE WITH RFC[25]Illegal XbaI site found at 72
Illegal PstI site found at 60 - 1000COMPATIBLE WITH RFC[1000]
References
- Chen, R., Cheng, H., Jin, P., Song, L., Yue, T., Hull, M., & Mansell, T. J. (2020). Nature Biotechnology, 38(10), 1107–1112. https://doi.org/10.1038/s41587-020-0571-7
None |