Lambert_GA 2021

Utilizing the phosphate range of 0-100μM and characterization protocol (See: Modified Protocol), we characterized the BBa_K2447000 phosphate sensor. The characterization curve (Figure 1) showed a linear, negative trend throughout phosphate concentrations ranging from 0-100μM. This data closely paralleled the predictive ODE model created by our 2020 team and the previous characterization data by NUS Singapore iGEM 2017.


Figure 1. Characterization curve for BBa_K2447000 for phosphate concentrations between 0μM and 100μM.