Background
MerR
The MerR family is a group of transcriptional regulators with similar N-terminal helix-turn-helix DNA binding regions and C-terminal effector binding regions that are specific to the effector recognized. The few MerR-like regulators that have been studied experimentally have been shown to activate suboptimal σ70-dependent promoters, in which the spacing between the -35 and -10 elements recognized by the σ factor is greater than the optimal 17±1 bp. So, how does it respond to heavy metal ions? Take MerR-pMerR as an example, it has several processes. 1. In the absence of Hg2+ and MerR, RNA polymerase preferentially transcribes from the merR promoter, increasing the amount of MerR present in the cell. 2. Once MerR binds to merOP, transcription of the MerR promoter is repressed and the DNA becomes bent and unwound at the operator sequence. RNA polymerase is recruited to the mer promoter, forming a ternary complex of DNA, MerR and RNA polymerase. 3. Binding of Hg2+ to one of two binding sites on the MerR make DNA distortion at the centre of the operator which cause the reorientation of the -35 and -10 sequences make them interact with the RNA polymerase σ70 subunit to form an open transcriptional complex and transcription is initiated. [1]
Experiment
Lysis gene expression
We have developed the lysis module (BBa_K2360000) and five metal detecting module for E. coli BL21. Combining the lysis module and detecting module, we have constructed five devices which can respond to different metal ions.
Because the lysis gene will be expressed when the detecting module makes a response to the metal ions, which will make bacterial cleavage, resulting in the decrease of OD600, we measured the growth curve of our engineering bacteria in different concentration of metal ions to prove its function.
File:Http://2017.igem.org/File:SCUT A PART NI.png
Figure 1. the growth curve of cadmium detecting device in different concentration of cadmium ions.
As shown in the growth curves of E. coli with cadmium detecting device (figure 2), the growth rate of E. coli BL21 is decline obviously after adding the concentration of Cd2+ from 10-8M to 10-5M, indicating that this device can detect the cadmium ions.
Specificity
We verified the detecting devices specificity of cadmium by adding Cd2+, Hg2+, Pb2+, Cr6+, Ni2+ to their culture mediums.
File:SCUT A PART CD S.PNG
figure 1. The growth of the E. coli with cadmium detecting device after adding different metal ions and ddH2O