Composite

Part:BBa_K1694024

Designed by: CHIH-HSUAN HSU   Group: iGEM15_NCTU_Formosa   (2015-09-15)
Revision as of 02:33, 19 September 2015 by SherryNCTU (Talk | contribs)

Pcons+B0034+Lpp-OmpA-N+scFv(Anti-EGFR)

Introduction:

Fig.1 Pcons+B0034+Lpp-OmpA-N+scFv(Anti-EGFR)

By ligating the constitutive promoter (BBa_J23101), strong ribosome binding site (BBa_B0034) and Lpp-OmpA-scFv, we were able to display scFv on the E. coli outer membrane continuously.
Having this part, we can co-transform with other parts in order to produce color as the detection signal.

This year we want to provide a customized platform. We provide two libraries of Pcon+RBS+OmpA-scFv and Pcons+RBS+Fluorescence+Ter into E. coli. Therefore, our customers can choose any scfv and any fluorescence protein. Our team will then co-transform the two plasmids, which helps us tailor our product to the wishes of our customers.

Experiment:

1.Cloning

After receiving the DNA sequences from the gene synthesis company, we recombined each scFv gene to PSB1C3 backbones and conducted a PCR experiment to check the size of each of the scFvs. The DNA sequence length of the scFvs are around 600~800 bp. In this PCR experiment, the scFv products size should be near at 850~1050 bp. The Fig. showed the correct size of the scFv, and proved that we successful ligated the scFv sequence onto an ideal backbone.

2.Co-transform

Fig.4 Pcons+RBS+Lpp-OmpA-N+Anti-EGFR
Fig.5 Pcons+RBS+RFP+Ter
Fig.6 Pcons+RBS+GFP+Ter

Cell staining experiment:
After cloning the part of anti-EGFR, we were able to co-transform anti-EGFR with different fluorescence protein into our E. coli.
The next step was to prove that our co-transformed product have successfully displayed scFv of anti-EGFR and expressed fluorescence protein.
To prove this, we conducted the cell staining experiment by using the co-transformed E. coli to detect the EGFR in the cancer cell line.


Fig.9 ~ Fig. 12 are our staining results:
Negative control:
There are red and green fluorescent anti-EGFR E. coli stick on the cell’s surfaces as the anti-EGFR probes on E. colis successfully detect and bind with EGFR.

Fig.9 As results,there is no green fluorescent E. coli stick on the cell’s surface as there is no specific scFv displayed around the E.coli.
Fig.10 As results,there is no red fluorescent E. coli stick on the cell’s surface as there is no specific scFv displayed around the E.coli.


Fig.11 There are green fluorescent anti-EGFR E. colis stick on the cell’s surfaces as the anti-EGFR probes on E. colis successfully detect and bind with EGFR.
Fig.12 There are red fluorescent anti-EGFR E. colis stick on the cell’s surfaces as the anti-EGFR probes on E. colis successfully detect and bind with EGFR.


Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    INCOMPATIBLE WITH RFC[12]
    Illegal NheI site found at 7
    Illegal NheI site found at 30
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal NgoMIV site found at 451
  • 1000
    COMPATIBLE WITH RFC[1000]


[edit]
Categories
Parameters
None