Regulatory
zinTp
Part:BBa_K896008:Experience
Designed by: Shih-Hao Chen Group: iGEM12_NYMU-Taipei (2012-09-22)
- Before 60 min, the fluorescence level of zinTp+GFP steadily increased, while BBa_I13522 (positive control) remained stable around 35000 au as time gone by. At 60 min, zinTp reached its maximum transcription rate so the fluorescence level stop increasing around 55000 au.
- This fig shows the fluorescence level of different cadmium concentration. We can see that BBa_I13522 remained stable from different cadmium concentration, while the fluorescence level of zinTp+GFP increased as the cadmium concentration increased. We could also tell that the transcription rate of zinTp is fairly low when there is no cadmium ion.
Applications of BBa_K896008
It can be used to detect cadmium ion when ligating with GFP.
User Reviews
UNIQ0f3f8f8f8ee37f5c-partinfo-00000000-QINU
No review score entered. iGEM Nagahama_2014 |
lac promoter (BBa_R0010) in the upper of the zinTp was removed from BBa_K896008 resulting to new parts [Part:https://parts.igem.org/wiki/index.php?title=Part:BBa_K896008 BBa_K1342005]. |
UNIQ0f3f8f8f8ee37f5c-partinfo-00000002-QINU