Part:BBa_K608352:Experience

Designed by: Theodhor Tiko   Group: iGEM11_Freiburg   (2011-09-14)
Revision as of 20:28, 21 September 2011 by UsernameV (Talk | contribs) (Applications of BBa_K608352)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.


Applications of BBa_K608352

We managed to perform a last-minute, "blind" -ie not knowing if the sequence of the insert was correct-, and preliminary OD-measurement testing of the part in conjuction with (BBa_K608351), as part of our temperature sensitive phage lysis cassette.


We later verified the part sequence. Please refer to our Project Results Page (http://2011.igem.org/Team:Freiburg/Results#Lysis_cassette) for more Info.


The OD values of the measurement are shown in the chart (please do bear in mind that this was a measurement done under deadline-stress, without the possibility to plan and perform something more concrete before the Wiki-Freeze)

LB with Cm (Chloramphenicol) was used as a blank before every (hourly) measurement


Freiburg11 LysisCassetteODmeasurement.jpg


Nr1: Insert is only part (BBa_K608351)
Nr2: Insert is only this part ((BBa_K608352))
Nr3: Both parts were correctly assembled (1:(BBa_K608351) + 2:(BBa_K608352))


Therefore (BBa_K608352) seems to be functioning properly. More tests are planned if time allows (ie wiki-unfreeze ;) )