Experiment:

The three subparts are ligated together step by step with sub-clone. To test the function of the device, both expression experiment and function test is necessary. As a result, we have test the size of the expressed proteins with SDS-page and Western blot. Besides, to test the efficiency of mercury binding, we also carried out the function test with ICP-AES, which can test the quantity of mercury binding by the bacteria with the device.