Coding

Part:BBa_K1159001:Experience

Designed by: TU Munich 2013   Group: iGEM13_TU-Munich   (2013-05-17)
Revision as of 21:42, 18 September 2015 by S138200 (Talk | contribs)

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K1159001

iGEM TU Eindhoven 2015

We as iGEM TU Eindhoven 2015 used NanoLuc in a BRET sensor together with mNeonGreen. Bioluminescence Resonance Energy Transfer is a physical process which can take place between fluorophores when they are in close proximity (1-10nm) [1]. An electron which has been transferred to its ‘excited state’ falls back to its ‘ground state’. The energy that is released by the electron falling back to its ground state is normally released in the form of light. In the case of Resonance Energy Transfer, however, the energy of the electron falling back to its ground state is coupled to a transition of an electron in the RET Acceptor from its ground state to the excited state (see Figure 1).

TU Eindhoven BRET Diagram.jpg

Figure 1: Simplified energy-level diagram of RET. A) Normally, an excited electron falls back to its ground state under the emission of light (a radiative transition). B) In the case of Resonance Electron Transfer, an excited electron in the donor falls back to its ground state. This transition is coupled to the excitation of an electron in the acceptor. This excited electron falls back normally under the emission of light.

The main goal of our project was to design a universal, modular biosensor that can detect molecules by using aptamers. NanoLuc worked very well for us. We've inserted NanoLuc in a pETDuet-1 vector together with Outer Membrane Protein X (OmpX) and a BsoBI-linker, which is a long and flexible GGSGGS-linker with two BsoBI restriction sites. Several experiments gave very strong results for NanoLuc.

TU Eindhoven BRET.jpg

We've characterized NanoLuc by performing a bioluminescence assay with the OmpX-NanoLuc construct. This gave the following results (see Figure 3).

TU Eindhoven Bioluminescence Results OmpX-NanoLuc.jpg

Figure 3: Bioluminescence results of our OmpX-NanoLuc construct.

We've also performed a bioluminescence assay for the construct that both contains OmpX-NanoLuc and OmpX-mNeonGreen. This gave the following results (see Figure 4). From this it can be concluded that both the construct were present, that NanoLuc worked well as a BRET donor and that mNeonGreen worked well as a BRET acceptor.

TU Eindhoven Bioluminescence Results OmpX-NanoLuc OmpX-mNeonGreen.jpg

Figure 4: Bioluminescence results of our complete construct, containing both NanoLuc and mNeonGreen.

References: Medintz I. and Hildebrandt N., Eds., FRET - Förster Resonance Energy Transfer. Weinheim, Germany: Wiley-VCH Verlag GmbH & Co. KGaA, 2013.

User Reviews

UNIQ5fd19cd99f2db659-partinfo-00000000-QINU

•••••

iGEM TU Eindhoven 2015

This part works very well. We used NanoLuc in a BRET sensor, connected to OmpX with a BsoBI-linker. When furimazine is added, NanoLuc will work as a donor, which means that the energy of an electron falling back to its ground state is coupled to a transition of an electron in the RET Acceptor from its ground state to the excited state. We used mNeonGreen as acceptor in this BRET sensor. For more information and further characterization, see the Applications section above.

UNIQ5fd19cd99f2db659-partinfo-00000002-QINU