Regulatory

Part:BBa_I721001

Designed by: Jeffrey Hofmann   Group: iGEM07_Brown   (2007-10-26)
Revision as of 12:18, 28 September 2024 by Pok430 (Talk | contribs)

Lead Promoter

Lead Promoter (Part 4) messed up EcoRI site

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal SapI.rc site found at 80



Part BBa_1721001 is the Lead Promoter.

Description
This part is designed to enable Lead Detection in a cell. When Lead (Pb +2) enters the cell, it will couple with the Lead Binding protein (NOT IN THIS PART), forming a dimer. This dimer will then bind to the Lead Promoter, which is contained within this part, BBa_I721001. BBa_I721001 contains the Lead Promoter sequence, and and must be combined with a functional Lead Binding Protein part for it to work.

This sequence was obtained using PCR from the genome of Ralstonia metallidurans. Biobrick cut sites were added using specific primers during PCR.

This part is not known to function. "PbrR691/promoter combinations in presence of lead nitrate give no GFP production and no AHL production compared to control. "

The figure below illustrates the layout of this sequence.

Sequence Layout of I721003

This part contains one section: A sequence for a Lead Promoter.


15 planned Lead Promoter and Lead Binding Protein Biobricks

Because of the different coding regions contained in this sequence, the Brown iGEM Team chose 15 different regions of the Pbr691 and PbrR691 sequences to extract. We attempted to create Biobricks from each of these 15 different sequences. Some contained only the PbrR Lead Binding Protein, some contained only the Pbr Promoter, and some parts contained both. The following diagram illustrates these different parts.

BBa_I721001 contains the Lead Promoter region.

Functional Layout of I721003

BBa_I721001 was designed to be a part of the Brown University Cellular Lead detector device. The BBa_I721001 Lead Promoter is intended to be combined with a Lead Binding Protein Part. Together, this Lead Detection System was designed to be attached to the Amplification system by Imperial College, (BBa_J37015), with GFP as the output of the device. The schematic for this project is below:

Overall Brown University iGEM 07 Design


Contribution

  • Group: iGEM24_HongKong-JSS

Lead biosensor

Our team used this part to construct a lead biosensor with E. coli. We aimed to create biosensors visible to the naked eye without special equipment, so we employed the dTomato chromoprotein, previously optimized by our team, as the reporter gene (BBa_K5152004).

We successfully validated our biosensor's ability to detect lead (100 µM lead (II) nitrate). The medium turns red due to dTomato expression. We obtained pellets from 1 mL of biosensor cultures after spinning at 8,000 g for 2 minutes.

100 uM Pb 12 hours
Fig. 1: Biosensor cells exposed to 100 µM lead (II) nitrate showed an observable red colour in the pellets. While there is a noticeable difference, the red colouration in the culture form is less obvious.

100 uM Pb 18 hours
Fig. 2: After 18 hours of incubation, the red colour in the pellet becomes visible. However, a slight red colour is observed in cells without added lead, indicating leaky expression.

The colour signal in the pellet becomes distinguishable after 12 hours of incubation, while the culture's signal is significant after 18 hours with lead. However, leaky red expression is observed if incubation exceeds 18 hours.

We also demonstrated that the reporter is concentration-dependent; the color intensity increases with higher lead concentrations. The figure below shows our biosensor after incubating with 0, 0.01, 0.1, 1, and 10 µM lead (II) nitrate solutions for 24 hours. The color differences are easily distinguishable.

0-10uM Pb 24 hrs
Fig. 3: The colour intensity of the biosensor cells increases with higher lead concentrations, suggesting that the biosensor design is concentration-dependent.

This suggests that our biosensor design is effective and could have broad applications.

[edit]
Categories
//chassis/prokaryote/ecoli
//direction/forward
//function/sensor/metal
//promoter
//regulation/positive
//rnap/prokaryote/ecoli/sigma70
Parameters
negative_regulators
positive_regulators1