Composite

Part:BBa_K2217013

Designed by: Mohammad Tarek Mansour   Group: iGEM17_AFCM-Egypt   (2017-09-23)
Revision as of 15:33, 11 October 2019 by Chenzijin (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)


CAG Promoter

We tried to improve CAG promoter at BBa_K1179069 by making it RFC 10 compatible. CMV enhancer + chicken beta-actin promoter, the part was improved by sequence adjustment to gene block synthesis requirements The sequence GGC was repeated 6 consecutive times starting at base 538 and a homopolymer run of 16 G bases is present starting at base 413 was reduced less than 9.

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]


Contribution:BM-AMU 2019

Summary:in this part, we made contributions to the quantitative characterization data of pCAG. We measured the strength of CAG promoter (pCAG) and compare it with other three promoters.

Our team built four kinds of plasmids: which are built based on pGuide, with the pCAG, pCMV, pEF1a, pUbiquitin activating the expression of GFP, and then the expression of GFP strength can reflect the promoter strength after building complete four plasmids. Transfect the plasmids respectively into 293 cells by liposome transfection, then we collected samples after 24/48 hours. Finally, compare GFP expression of CAG promoter, CMV, EF1a, Ubiquitin in 293 cells by flow cytometry. The experimental procedures used in this assay involved measuring fluorescence using Median Fluorescence Intensity . Thus, the absolute values are arbitrary units, and cannot be directly compared to other systems. Our experiment, however, does reveal the relative strength of the CAG promoter device as compared to three promoters. we obtained the result of the diagram below:

Fig.1 the fluorescence for four different promoters. The measurement units are arbitrary units of fluorescence.


Fig.2 relative promoter strength of CAG, comparing with CMV, Ubiquitin, EF1a. (The fluorescence in 24h were weaker than that in 48h among all of these promoters.In 48h,PCMV had about 2-fold greater fluorescence than the pCAG. pUbiqutin had about 1.1-fold to 1.2-fold greater fluorescence than the pCAG. pEF1a had about 1.5-fold greater fluorescence than the pCAG. The measurement units are arbitrary units of fluorescence.)
[edit]
Categories
//awards/part_collection
Parameters
function