Part:BBa_K2789020
__TOC__
The protocol for measuring the total phosphorus
Kit: made by HANGZHOU LOHAND BIOLOGICAL Co. Ltd.
Principle: Ammonium molybdate spectrophotometric method
Steps:
1. Add one pack of Agent1 to 5ml desired liquid*.
2. Shake it thoroughly to mix the solution.
3. Put it into a autoclave setting at 121°C for 20 minutes to decompose the matter in liquid.
4. When cooling down, add a pack of Agent2 and mix it thoroughly again.
5. Add 7 drops of Activing AgentP .
6. Vortex the solution for 1 minute.
7. Use a spectrophotometer to measure OD value at 700nm.
- The liquid should be dilute to make the total phosphorus at 1-20mg/L.
PPK may be in the WT E.coli
We can see a 10% absorption in the experiment which may indicate the PPK works well. Additional Information We performed colony PCR to proof the exist of PPK in our transformed bacteria and found that WT may contain PPK gene as well but with a lower copy number. The blank control group indicated there is no pollution in the PCR system. This may explain why the function of ppk is not so obvious.
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25INCOMPATIBLE WITH RFC[25]Illegal AgeI site found at 53
- 1000INCOMPATIBLE WITH RFC[1000]Illegal SapI.rc site found at 732
</html>
chassis | E.coli |