Composite

Part:BBa_K1694035

Designed by: Chen Yu, Chang   Group: iGEM15_NCTU_Formosa   (2015-09-15)
Revision as of 07:01, 22 September 2015 by AmberLin (Talk | contribs)

Pcons+B0034+Lpp-OmpA-N+scFv(Anti-HER2)+B0030+GFP+J61048

Introduction:

Fig.1 Pcons+RBS+Lpp-OmpA-N+anti-HER2+RBS+GFP+Ter

Transformation of single plasmid

To prove that our scFv can actually bind on to the antigen on cancer cells, we connected each scFv with a different fluorescence protein. Therefore, we could use fluorescence microscope to clearly observe if the E. coli has produced scFv proteins. Currently,we built three different scFv connected with their respectively fluorescence protein, which are anti-VEGF+GFP, anti-EGFR+RFP, anti-HER2+BFP. When conducting cell staining, we can identify the antigen distribution on cancer cells by observing the fluorescence. Furthermore, if we use the three scFv simultaneously, we can also detect multiple markers. Besides,we built 3 extra parts which is each scFv connected with green fluorescence protein.

Fig.2 Transformation of single plasmid


Experiment

1.Cloning

Fig.3 The PCR result of the Pcons+B0034+Lpp-OmpA-N+scFv(Anti-HER2)+B0030+GFP+J61048. The DNA sequence length is around 1900~2100 bp, so the PCR products should appear at 2100~2300 bp.

After assemble the DNA sequences from the basic parts, we recombined each Pcons+B0034+Lpp-OmpA-N+scFv(Anti-HER2)+B0030+GFP+J61048 gene to pSB1C3 backbones and conducted a PCR experiment to check the size of each part. The DNA sequence length of the these parts are around 1900~2100 bp. In this PCR experiment, the PCR products size should be near at 2100~2300 bp. The Fig.3 showed the correct size of this part, and proved that we successful ligated the sequence onto an ideal backbone.

Fig.4 Pcons+B0034+Lpp-OmpA-N+scFv(anti-HER2)+B0030+GFP+J61048


2. Transformation of single plasmid


(1) Cell staining experiment: After creating the part of scFv and transforming them into our E. coli, we were going to prove that our detectors have successfully displayed scFv of anti-EGFR. To prove this, we have decided to undergo the cell staining experiment by using our E. coli to detect the EGFR in the SKOV-3 cancer cell lines. SKOV-3 is a kind of epithelial cell that expressed markers such as EGFR.

(2) Staining results:

Fig.18 As results,there is no green fluorescent E. coli stick on the cell’s surface as there is no specific scFv displayed around the E. coli.
Green fluorescent anti-HER2 E. coli stick on the cell’s surface as the anti-HER2 probes on E. coli successfully detect and bind with HER2.

Modeling

In the modeling part, we discover optimum protein expression time by using the genetic algorithm in Matlab.
We want to characterize the actual kinetics of this Hill-function based model that accurately reflects protein expression time.
When we have the simulated protein expression rate, the graph of protein production versus time can be drawn. Thus, we get the optimum protein production time Compared with the simulated protein expression rate of time, our experiment data quite fit the simulation.


From this graph, the orange curve is the simulated protein expression. The blue curve is our experimental data. By comparing the orange curve and the blue curve, the blue curve quite fit the simulation. The orange curve reaches peak after growing about 15 hours. Thus, we can know that the E.Cotector can have maximum efficiency at this point.


Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    INCOMPATIBLE WITH RFC[12]
    Illegal NheI site found at 7
    Illegal NheI site found at 30
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal BglII site found at 741
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal NgoMIV site found at 451
    Illegal NgoMIV site found at 1846
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal BsaI.rc site found at 1762


[edit]
Categories
Parameters
None