Difference between revisions of "Part:BBa J428100"
Alejovigno (Talk | contribs) |
Alejovigno (Talk | contribs) |
||
Line 2: | Line 2: | ||
__NOTOC__ | __NOTOC__ | ||
<partinfo>BBa_J428100 short</partinfo> | <partinfo>BBa_J428100 short</partinfo> | ||
+ | |||
Non-fluorescent negative control for InterLab studies 2022. | Non-fluorescent negative control for InterLab studies 2022. | ||
It uses the same elements as the fluorescent constructs but expresses a non-fluorescent protein (LuxR). | It uses the same elements as the fluorescent constructs but expresses a non-fluorescent protein (LuxR). | ||
Line 7: | Line 8: | ||
It imposes the same burden on the bacteria for a more fair growth comparison between the different devices. | It imposes the same burden on the bacteria for a more fair growth comparison between the different devices. | ||
+ | Specially designed for the Interlab_2022_DoubleConstructs and Interlab_2022_ThreeColors studies. | ||
− | + | It can be used as negative control for fluorescent measurements in general. | |
[[File:EngCom_2022_J428100.png|500px|thumb|center|alt=J428100.|Figure 1. SBOL Visual representation of the device [https://parts.igem.org/Part:BBa_J428100 J428100] from [https://technology.igem.org/interlabs 2022 Interlab studies.] ]] | [[File:EngCom_2022_J428100.png|500px|thumb|center|alt=J428100.|Figure 1. SBOL Visual representation of the device [https://parts.igem.org/Part:BBa_J428100 J428100] from [https://technology.igem.org/interlabs 2022 Interlab studies.] ]] |
Revision as of 20:48, 8 June 2022
Interlab_NegC
Non-fluorescent negative control for InterLab studies 2022. It uses the same elements as the fluorescent constructs but expresses a non-fluorescent protein (LuxR). It includes a region upstream of the promoter to insulate transcription, a promoter (J23106), a RiboJ to insulate translation, the B0032 RBS, the CDS for the LuxR protein, and an efficient transcriptional terminator (rnpB_T1). It imposes the same burden on the bacteria for a more fair growth comparison between the different devices.
Specially designed for the Interlab_2022_DoubleConstructs and Interlab_2022_ThreeColors studies.
It can be used as negative control for fluorescent measurements in general.
Sequence and Features
Assembly Compatibility:
- 10COMPATIBLE WITH RFC[10]
- 12INCOMPATIBLE WITH RFC[12]Illegal NheI site found at 71
Illegal NheI site found at 94 - 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]