This page is meant to explain the experiments that were done to determine the best protocol for the characterization of transcriptional terminators with the two platforms [[Part:BBa_K731700|BBa_K731700]] and [[Part:BBa_K731710|BBa_K731710]]. Theoretically, the protocol works for any platform that exploits a bicistronic message encoding two fluorescent proteins.
  
In this page we are really proud to introduce you the protocol we (Giacomo and Anna) developed for the characterization transcriptional terminators' effects on gene expression. (Tested on [[Part:BBa_K7|BBa_J64997]])
+
The definitive protocol we developed was used for the ''in vivo'' characterization of both the platforms using two terminators that, in this way, were characterized too. More specifically, they are the rrnB T1 from ''E. coli'' ([[Part:BBa_K731722|BBa_K731722]]) and T7 bacteriophage wild type terminator ([[Part:BBa_K731721|BBa_K731721]]).
  
The develop of this protocol cost us not only sleepless night but also wasted sunny and beautiful weekend so take a hot cup of tea and read it all.
+
Difficulties in obtaining reliable data are often encountered when approaching this task, but with this easy protocol we obtained reliable results and really low standard deviations.  
  
 +
  
 
'''''IN VIVO'' ANALYSIS'''
 
'''''IN VIVO'' ANALYSIS'''
Line 12: Line 13:
  
 
'''BEFORE STARTING:'''
 
'''BEFORE STARTING:'''
 
  
 
* In order to analyze terminators through this method is necessary to follow the entire procedure with both the platform without intervening terminator (control) and the platform with terminator (sample).
 
* In order to analyze terminators through this method is necessary to follow the entire procedure with both the platform without intervening terminator (control) and the platform with terminator (sample).
Line 19: Line 19:
 
'''CELLS GROWTH AND SAMPLES PREPARATION (starting from a glycerol stock):'''
 
'''CELLS GROWTH AND SAMPLES PREPARATION (starting from a glycerol stock):'''
  
 +
* 100 ul of cells (i.e. ''Escherichia coli'' BL21(DE3) pLysS) tranformed with the platform (control or sample) in 10 ml fresh Luria Bertani medium (LB)
  
* 100ul of cells (i.e. BL21(DE3) pLysS) tranformed with the platform (control or sample) in 10 ml fresh Luria Bertani medium (LB)
+
NOTE 1: Antibiotic are at concentration of 0.1 mg/ml ampicillin and 0.035 mg/ml cloranphenicol
 
+
NOTE1:Antibiotic are at concentration of 0.1mg/ml ampicillin and 0.035mg/ml cloranphenicol
+
  
NOTE2:Four glycerol stocks for both control and sample will give you a good level of significance
+
NOTE 2: Four glycerol stocks for both control and sample will give you a good level of significance
  
*Grow the cultures at 37°C in the termoshaker until optical density at 600nm (O.D.) ~ 0.4 (the O.D. at which you stop the sample is not important until it is major than 0.2.)
+
*Grow the cultures at 37°C in the termoshaker until optical density at 600 nm (O.D.) ~ 0.4 (the O.D. at which you stop the sample is not important until it is major than 0.2.)
  
 
*(chill on ice for the whole duration of this point) Dilute samples to OD 0.2 in order to have the same O.D. at the moment of induction.
 
*(chill on ice for the whole duration of this point) Dilute samples to OD 0.2 in order to have the same O.D. at the moment of induction.
**x = 10ml*0.2 O.D./0.4 O.D. (where x are the ml of culture you need to take from the culture in the termoshaker)
+
**''x'' = 10 ml * 0.2 O.D./ 0.4 O.D. (where ''x''are the ml of sample you need to take from the culture in the thermoshaker)
**LB = 10ml-x (where LB are the ml of LB you need to add to x to obtain OD 0.2)
+
**LB = 10 ml- ''x'' (where LB are the ml of LB you need to add to ''x''to obtain OD 0.2)
*Grow 37°C in the termoshaker until O.D. ~ 0.6.
+
*Grow 37°C in the thermoshaker until O.D. ~ 0.6.
*Induce with 0.5mM Isopropyl β-D-1-thiogalactopyranoside (IPTG).
+
*Induce with 0.5 mM Isopropyl β-D-1-thiogalactopyranoside (IPTG).
*3 hours induction at 37°C in the termoshaker.
+
*3 hours induction at 37°C in the thermoshaker.
*Chill falcon on ice
+
*Chill falcons on ice
*Move 1ml of induced culture to an eppendorf.
+
*Move 1 ml of induced culture to an eppendorf.
*Sonication (3 repetition of 10 s 50% amplitude sonication and 30 s of pause).  
+
*Sonication (3 repetition of 10 seconds 50% amplitude sonication each 30 seconds).  
*1.5 min centrifuge (4000rpm).
+
*1.5 min centrifuge (4000 rpm).
*Move supernatant from eppendorf to cuvette.
+
*Move supernatant from eppendorf to a cuvette.
*Add 1 mL buffer (i.e.: PBS)
+
*Add 1 ml buffer (i.e.: phosphate buffer saline (PBS), 0.0067 M PO4 without Calcium or Magnesium, Cat number BE17-516F)
*Leave the cuvettes over night (O.N.) it the 4°C fridge
+
*Leave the cuvettes over night (O.N.) it the 4°C refrigerator
 
*Fluorimetric measurements
 
*Fluorimetric measurements
  
Line 50: Line 49:
 
==PROTOCOL DEVELOPMENT:==
 
==PROTOCOL DEVELOPMENT:==
  
'''Emission and Excitation parameter choise:'''
+
'''Emission and Excitation parameter choice:'''
  
The two proteins in use in BBa_K731700 and BBa_K731710 are mCherry and A206K Venus (mVenus), respectively  upstream and downstream of the terminator. After excitation of the two proteins with standard parameters, we noticed a huge difference in fluorescence intensity between the two peaks, as mVenus emission peak was about 10 times stronger than the mCherry peak. Moreover, the two fluorescent proteins presented excitation and emission peaks very close to each other. This feature may cause unwanted interferences of the scattering effect caused by the excitation ray.
+
The two proteins in use in BBa_K731700 and BBa_K731710 are mCherry and A206K Venus (mVenus), respectively  upstream and downstream of the terminator. After excitation of the two proteins with standard parameters, we noticed a huge difference in fluorescence intensity between the two peaks, as mVenus emission peak was about 10 times stronger than the mCherry peak.
// Due to the scattering effect caused by the closeness of the two peaks, interferences in the measure can occur.
+
  
 
In this case a shift of the brighter protein (mVenus) excitation wavelength toward smaller wavelength can bring two main benefits:
 
In this case a shift of the brighter protein (mVenus) excitation wavelength toward smaller wavelength can bring two main benefits:
Line 64: Line 62:
 
Here is a summary of the wavelengths used to take the measurements with BBa_K731700 and BBa_K731710:
 
Here is a summary of the wavelengths used to take the measurements with BBa_K731700 and BBa_K731710:
  
The emission and excitation wavelengths must be aimed at achievement of the maximum distance between the two points at which you take emission measurements and the maximum comparability in terms of fluorescence intensity according to the limits imposed by the two fluorescent proteins in use.
 
 
 
'''Example:''' The two proteins in use in BBa_K731700 and BBa_K731710 are mCherry and A206K Venus (mVenus). After excitation of the two proteins with standard parameters we note a huge difference in fluorescence intensity between the two proteins; moreover the proximity between the excitation wavelenght and the emission peak can easily influence the measurements.
 
In this case a shift of the brighter protein (mVenus) excitation wavelength toward smaller wavelength can bring two main benefits:
 
* A decrease in emission peak's fluorescence intensity
 
* A larger distance between the excitation wavelength and the emission peak's wavelength
 
 
 
The proximity of the emission and excitation peaks of the less bright protein (mCherry) could also cause unwanted interferences; to avoid this possibility its emission is measured at a little higher wavelength than the emission peak.
 
Here is a summary of the wavelengths used to take the measurements with BBa_K731700 and BBa_K731710:
 
  
  
Line 88: Line 75:
 
|mCherry
 
|mCherry
 
|587
 
|587
|609
+
|610
 
|587
 
|587
 
|615
 
|615
Line 102: Line 89:
 
</em> </p>
 
</em> </p>
 
[[Image:Wls_K731700_570V.jpg]] [[Image:Wls_K731710_520V.jpg]]  
 
[[Image:Wls_K731700_570V.jpg]] [[Image:Wls_K731710_520V.jpg]]  
<p style="width:900px; margin-bottom:60px; text-align:justify "><em><strong>CHART 1A/B:</strong> ''Emission scan of BBa_K731700 (A) and BBa_K731710 (B) with standard and modified excitation wavelenght (instrument: Varian Cary Eclipse, voltage: 570 V (A) and 520 V (B)) ''<br/>
+
<p style="width:900px; margin-bottom:60px; text-align:justify "><em><strong>CHART 1A/B:</strong> ''Emission scan of BBa_K731700 (A) and BBa_K731710 (B) with standard and modified excitation wavelength. The measurements were taken with a Varian Cary Eclipse spectrofluorimeter, with 5nm slit and a voltage of 570 V (A) and 520 V (B)) ''<br/>
 
</em></p>
 
</em></p>
 
'''Sonication of the samples:'''
 
'''Sonication of the samples:'''
  
In order to reduce the scattering (signal due to excitation light in proximity of the excitation wavelength) and to have a clearer signal, we decided to sonicate our sample before measure them. Both the improvements are due to the lower O.D. of a sonicated sample compared to a cell suspension sample. A higher O.D. means a decrease in the amount of light emitted by the fluorescent proteins that reach the sensor (light that), a decrease in the light that actually reach the fluorescent proteins and an icrease of the excitation light that is reflected to the sensor (increase in scattering).
+
In order to reduce the scattering due to excitation light and thus to have a clearer signal, we decided to sonicate our sample before measure them. Both the improvements are due to the lower O.D. of a sonicated sample compared to a cell suspension sample. A higher O.D. causes a decrease in light intensity emitted by the fluorescent proteins that reach the sensor, a decrease in the exciting light that actually reach the fluorescent proteins and an increase in the excitation light that is reflected to the sensor (increase in scattering).
  
  
 
<div style="text-align:center">
 
<div style="text-align:center">
 
[[Image:Sonication.jpg]]
 
[[Image:Sonication.jpg]]
<p margin-bottom:60px; text-align:center "><em><strong>CHART 2:</strong> ''Sonicated sample vs Cell suspension sample''<br/>
+
<p margin-bottom:60px; text-align:center "><em><strong>CHART 2:</strong> ''Comparison between a sonicated sample and a cells suspension sample''<br/>
 
</em> </p>
 
</em> </p>
 
</div>
 
</div>
Line 117: Line 104:
 
'''Test on different colonies:'''
 
'''Test on different colonies:'''
  
The use of glycerol stock instead of O.N cultures makes the procedure easier and faster. Glycerol stocks come however from the same colony so it was necessary to test the platform with cultures of different origin in order to find eventual differences in the behavior.
+
The use of glycerol stock instead of O.N cultures makes the procedure easier and faster. However, glycerol stocks come from the same colony; to verify the consistency of our results we tested some different colonies from two different plates.
 
+
  
 
[[Image:Coloniesjpg.jpg]][[Image:Statcolony.jpg]]
 
[[Image:Coloniesjpg.jpg]][[Image:Statcolony.jpg]]
 
<p style="width:900px; margin-bottom:60px; text-align:justify"><em>
 
<p style="width:900px; margin-bottom:60px; text-align:justify"><em>
  
<strong>CHART 3:</strong> ''Behavaior of different colonies.''
+
<strong>CHART 3:</strong> ''Fluorescence emission raw peaks of two cultures from colonies from different plates.''<br/>
  
<strong>TABLE 2:</strong> ''The table shows the statistic analysis performed on the data in CHART 3. Neither the proteins peaks of the two plates nor their ratio are significantly different (the result of ‘0 min after sonication (A206K Venus plate 1 vs A206K Venus plate 2)is considered a false positive since the other two times show no significant difference).''<br/>
+
<strong>TABLE 2:</strong> ''The table shows the statistic analysis performed on the data in CHART 3. Neither the proteins peaks of the two plates nor their ratio are significantly different (the result of "0 min after sonication (A206K Venus plate 1 vs A206K Venus plate 2)" is considered a false positive since the other two times show no significant difference).''<br/>
 
</em> </p>
 
</em> </p>
  
 
'''Different concentrations of inducing agent:'''
 
'''Different concentrations of inducing agent:'''
  
The use of different concentration of inducing agent should not influence the ratio between the fluorescence intensity of the two proteins. Nevertheless we tested two different concentration to verify the veracity of this statement.
+
The use of different concentration of inducing agent should not influence the ratio between the fluorescence intensity of the two proteins. Nevertheless the inducing agent concentration may have influence on the quantity of proteins synthesized. We tested two different concentration of isopropyl β-D-1-thiogalactopyranoside (IPTG).
  
'''Example:'''Two identical cultures are grown in LB until O.D. 0.6 and then iduced with different IPTG concentration (0.1 mM and 0.5 mM). Starting from induction time 0, withdraw 1 mL of culture at predetermined times (in this case all the times after 90 min miss cause of overflow in mVenus fluorescence intensity). Every time you withdraw 1 mL of culture, you have to prepare the sample for the fluorimetric measurements according to the protol shown in the beginning of this page (start from the sonication point).
 
  
 
[[Image:IPTGconcchart_inductiontime.jpg‎]][[Image:Statiptg.jpg]]
 
[[Image:IPTGconcchart_inductiontime.jpg‎]][[Image:Statiptg.jpg]]
Line 138: Line 123:
 
<p style="width:900px; margin-bottom:60px; text-align:justify"><em>
 
<p style="width:900px; margin-bottom:60px; text-align:justify"><em>
  
<strong>CHART 4:</strong> ''Behavaior at different concentration of inducing agent (IPTG).''
+
<strong>CHART 4:</strong> ''Raw emission peaks of cultures induced with 0.1 mM or 0.5 mM IPTG. The measurements were taken just after induction (time 0) and after 90 minutes (time 1).''<br/>
  
<strong>TABLE 3:</strong> ''The table shows the statistic analysis permormed on the data in CHART 4. There is no significant differences between the two samples at induction time 0 min; significant differences are instead shown between the samples at induction time 90 min. The t-tests also show that the % increase in protein expression between 0.1mM e 0.5mM is the same in the two proteins. ''<br/>
+
<strong>TABLE 3:</strong> ''The table shows the statistic analysis performed on the data in CHART 4. There is no significant difference between the two samples with different IPTG concentration at time 0; significant differences are instead shown between the samples at induction time 90 min. The t-tests also show that the % increase in protein expression between 0.1 mM e 0.5 mM is the same in the two proteins. ''<br/>
 
</em> </p>
 
</em> </p>
  
 
'''O.D. equalization:'''
 
'''O.D. equalization:'''
  
This point allows to have low standard deviation and variability in the data.
+
The apparent termination  efficiency (Ea), is defined in literature <cite>Nojima</cite> as ''Ea'' =1-(''Vs''/''Cs''×''Cc''/''Vc'') ,
 +
where ''Vs'' is the A206K Venus peak’s intensity of the construct with the terminator of interest inserted in the prefix-suffix linker, ''Vc'' is the A206K Venus peak’s intensity of the control construct without intervening terminator, ''Cs'' is the mCherry peak’s intensity of the construct with the terminator inserted and ''Cc'' is the mCherry peak’s intensity of the control construct
 +
 
 +
''Ea'' is composed of two components: the first due to the mVenus variation, the second to the mCherry variation.
 +
We called the former the ”raw” termination efficiency (Er=1-Vs/Vc), as it considers just the downstream gene contribution; the latter is the relative increase in upstream gene expression (RI= Cs/Cc). To distinguish these two components we had to compare each emission raw peak with the relative peak in the control construct. 
 +
To make the results reliable and accurate we decided to equalize the optical densities (O.D.) of the cultures to be compared before the induction.
 +
Briefly, at a certain point of the cultures growth, we measured the O.D. On the basis of these measurements, we diluted the samples to an O.D. of exactly 0.2. When they reached O.D. 0.6,  the protein synthesis was induced with  0.5 mM IPTG.
 +
The effect on the final results of this additional step  in the protocol is shown below (FIGURE 3). mCherry and mVenus  kinetics were further investigated, and the variations in ''Er'', ''RI'' and ''Ea'' were analyzed over a wide time lapse after the initial term of fluorescence stabilization.
 +
 
 +
 
 +
<div style="text-align:center">[[Image:Rawpeaksintime.jpg]]</div>
 +
<p style="width:600px; margin-left:150px; margin-bottom:60px;
 +
text-align:justify "><em><strong>FIGURE 1.</strong> '''Raw fluorescence emission peaks in time.'''<br/> (A) the mCherry raw peaks obtained from the measurements with the T7 promoter platform (BBa_K731700). (B) mVenus raw peaks obtained with the tac promoter platform (BBa_K731710). The samples were left overnight in the refrigerator, allowing fluorescence stabilization (protein folding and chromophore oxidation <cite>Shaner</cite>). Note that the X axis of the chart’s right side expresses the days after sonication and not the hours. The same is for the following charts.
 +
</em> </p>
 +
 
 +
 
 +
<div style="text-align:center">[[Image:EaErRIintimeptac.jpg]]</div>
 +
<p style="width:600px; margin-left:150px; margin-bottom:60px;
 +
text-align:justify "><em><strong>FIGURE 2.</strong> '''Ea, Er and RI in time.'''<br/> Left and right panels show the apparent and raw termination efficiency, respectively. The bottom chart represents the increase in mCherry expression compared to the control construct without intervening terminator. Data from BBa_K731710 measurements.
 +
</em> </p>
 +
 
 +
While raw peaks are quite variable, especially with the control construct, the termination efficiencies are stable in time.
 +
Both the mCherry raw emission and the relative increase in its expression is more variable than mVenus relative quantities. We saw this in all our experiments but we have no explanation to this at all.
 +
We tested the consequences of the O.D. equalization additional step measuring cultures which O.D.s were and were not equalized before induction,
 +
 
 +
<div style="text-align:center">[[Image:ODequalized_or_not_all.jpg]]</div>
 +
<p style="width:600px; margin-left:150px; margin-bottom:60px;
 +
text-align:justify "><em><strong>FIGURE 3.</strong> '''Comparison between results obtained equalizing or not cultures' O.D.s before induction'''<br/> The chart shows Er, RI and Ea kinetics obtained equalizing or not the coltures' O.D.s before induction. These data are calculated from measurements with BBa_K731700 (the T7 promoter platform).
 +
</em> </p>
 +
 
 +
From the data represented above we derived two main conclusions:
 +
*the results seem to stabilize well 13 hours after sonication, while before that time their variability is still considerable.
 +
*as we could expect, the O.D.s equalization step decrease the variability in Er and RI, while has less influence on Ea.
 +
Moreover, it is evident a higher variability in data obtained with the T7 terminator, if compared with those obtained with the E. coli terminator. We report this observation, but can’t explain it.
 +
 
 +
 
 +
'''Conclusion.'''
 +
 
 +
According to our results, the minor standard deviation is achieved exciting mVenus at 485 nm and measuring mCherry emission at 615 nm; sonicating the sample, incubating at 4°C and taking measurements about 13 hours later. After that, the results seem stable  for several days .
 +
 
 +
''"You can sonicate the evening before holidays, and measure when you come back" [Giaco the dwarf]''
 +
 
 +
All the measurements were taken in quadruplicate (4 sonicated samples from the same culture), and repeated the next day. 
 +
We limited our analysis on two fluorescent proteins, two promoters and two terminators; many other combination could be tested.
 +
 
 +
==References==
 +
<biblio>
 +
#Shaner pmid=16299475
 +
##Nojima pmid=16379390
 +
 
 +
</biblio>

Latest revision as of 17:20, 26 October 2012

This page is meant to explain the experiments that were done to determine the best protocol for the characterization of transcriptional terminators with the two platforms BBa_K731700 and BBa_K731710. Theoretically, the protocol works for any platform that exploits a bicistronic message encoding two fluorescent proteins.

The definitive protocol we developed was used for the in vivo characterization of both the platforms using two terminators that, in this way, were characterized too. More specifically, they are the rrnB T1 from E. coli (BBa_K731722) and T7 bacteriophage wild type terminator (BBa_K731721).

Difficulties in obtaining reliable data are often encountered when approaching this task, but with this easy protocol we obtained reliable results and really low standard deviations.


IN VIVO ANALYSIS

BEFORE STARTING:

  • In order to analyze terminators through this method is necessary to follow the entire procedure with both the platform without intervening terminator (control) and the platform with terminator (sample).


CELLS GROWTH AND SAMPLES PREPARATION (starting from a glycerol stock):

  • 100 ul of cells (i.e. Escherichia coli BL21(DE3) pLysS) tranformed with the platform (control or sample) in 10 ml fresh Luria Bertani medium (LB)

NOTE 1: Antibiotic are at concentration of 0.1 mg/ml ampicillin and 0.035 mg/ml cloranphenicol

NOTE 2: Four glycerol stocks for both control and sample will give you a good level of significance

  • Grow the cultures at 37°C in the termoshaker until optical density at 600 nm (O.D.) ~ 0.4 (the O.D. at which you stop the sample is not important until it is major than 0.2.)
  • (chill on ice for the whole duration of this point) Dilute samples to OD 0.2 in order to have the same O.D. at the moment of induction.
    • x = 10 ml * 0.2 O.D./ 0.4 O.D. (where xare the ml of sample you need to take from the culture in the thermoshaker)
    • LB = 10 ml- x (where LB are the ml of LB you need to add to xto obtain OD 0.2)
  • Grow 37°C in the thermoshaker until O.D. ~ 0.6.
  • Induce with 0.5 mM Isopropyl β-D-1-thiogalactopyranoside (IPTG).
  • 3 hours induction at 37°C in the thermoshaker.
  • Chill falcons on ice
  • Move 1 ml of induced culture to an eppendorf.
  • Sonication (3 repetition of 10 seconds 50% amplitude sonication each 30 seconds).
  • 1.5 min centrifuge (4000 rpm).
  • Move supernatant from eppendorf to a cuvette.
  • Add 1 ml buffer (i.e.: phosphate buffer saline (PBS), 0.0067 M PO4 without Calcium or Magnesium, Cat number BE17-516F)
  • Leave the cuvettes over night (O.N.) it the 4°C refrigerator
  • Fluorimetric measurements



PROTOCOL DEVELOPMENT:

Emission and Excitation parameter choice:

The two proteins in use in BBa_K731700 and BBa_K731710 are mCherry and A206K Venus (mVenus), respectively upstream and downstream of the terminator. After excitation of the two proteins with standard parameters, we noticed a huge difference in fluorescence intensity between the two peaks, as mVenus emission peak was about 10 times stronger than the mCherry peak.

In this case a shift of the brighter protein (mVenus) excitation wavelength toward smaller wavelength can bring two main benefits:

  • A decrease in emission peak's fluorescence intensity
  • A larger gap between the excitation wavelength and the emission peak's wavelength


Moreover, the less bright protein (mCherry) was measured at a slightly higher wavelength than the peak seen in the emission spectrum.

Here is a summary of the wavelengths used to take the measurements with BBa_K731700 and BBa_K731710:


Standard Excitation (nm) Standard Emission (nm) Modified Excitation (nm) Modified Emission (nm)
mCherry 587 610 587 615
mVenus 515 528 485 528

TABLE 1: Standard and modified excitation and emission wavelengths

Wls K731700 570V.jpg Wls K731710 520V.jpg

CHART 1A/B: Emission scan of BBa_K731700 (A) and BBa_K731710 (B) with standard and modified excitation wavelength. The measurements were taken with a Varian Cary Eclipse spectrofluorimeter, with 5nm slit and a voltage of 570 V (A) and 520 V (B))

Sonication of the samples:

In order to reduce the scattering due to excitation light and thus to have a clearer signal, we decided to sonicate our sample before measure them. Both the improvements are due to the lower O.D. of a sonicated sample compared to a cell suspension sample. A higher O.D. causes a decrease in light intensity emitted by the fluorescent proteins that reach the sensor, a decrease in the exciting light that actually reach the fluorescent proteins and an increase in the excitation light that is reflected to the sensor (increase in scattering).


Sonication.jpg

CHART 2: Comparison between a sonicated sample and a cells suspension sample

Test on different colonies:

The use of glycerol stock instead of O.N cultures makes the procedure easier and faster. However, glycerol stocks come from the same colony; to verify the consistency of our results we tested some different colonies from two different plates.

Coloniesjpg.jpgStatcolony.jpg

CHART 3: Fluorescence emission raw peaks of two cultures from colonies from different plates.
TABLE 2: The table shows the statistic analysis performed on the data in CHART 3. Neither the proteins peaks of the two plates nor their ratio are significantly different (the result of "0 min after sonication (A206K Venus plate 1 vs A206K Venus plate 2)" is considered a false positive since the other two times show no significant difference).

Different concentrations of inducing agent:

The use of different concentration of inducing agent should not influence the ratio between the fluorescence intensity of the two proteins. Nevertheless the inducing agent concentration may have influence on the quantity of proteins synthesized. We tested two different concentration of isopropyl β-D-1-thiogalactopyranoside (IPTG).


IPTGconcchart inductiontime.jpgStatiptg.jpg

CHART 4: Raw emission peaks of cultures induced with 0.1 mM or 0.5 mM IPTG. The measurements were taken just after induction (time 0) and after 90 minutes (time 1).
TABLE 3: The table shows the statistic analysis performed on the data in CHART 4. There is no significant difference between the two samples with different IPTG concentration at time 0; significant differences are instead shown between the samples at induction time 90 min. The t-tests also show that the % increase in protein expression between 0.1 mM e 0.5 mM is the same in the two proteins.

O.D. equalization:

The apparent termination efficiency (Ea), is defined in literature Nojima as Ea =1-(Vs/Cs×Cc/Vc) , where Vs is the A206K Venus peak’s intensity of the construct with the terminator of interest inserted in the prefix-suffix linker, Vc is the A206K Venus peak’s intensity of the control construct without intervening terminator, Cs is the mCherry peak’s intensity of the construct with the terminator inserted and Cc is the mCherry peak’s intensity of the control construct

Ea is composed of two components: the first due to the mVenus variation, the second to the mCherry variation. We called the former the ”raw” termination efficiency (Er=1-Vs/Vc), as it considers just the downstream gene contribution; the latter is the relative increase in upstream gene expression (RI= Cs/Cc). To distinguish these two components we had to compare each emission raw peak with the relative peak in the control construct. To make the results reliable and accurate we decided to equalize the optical densities (O.D.) of the cultures to be compared before the induction. Briefly, at a certain point of the cultures growth, we measured the O.D. On the basis of these measurements, we diluted the samples to an O.D. of exactly 0.2. When they reached O.D. 0.6, the protein synthesis was induced with 0.5 mM IPTG. The effect on the final results of this additional step in the protocol is shown below (FIGURE 3). mCherry and mVenus kinetics were further investigated, and the variations in Er, RI and Ea were analyzed over a wide time lapse after the initial term of fluorescence stabilization.


Rawpeaksintime.jpg

FIGURE 1. Raw fluorescence emission peaks in time.
(A) the mCherry raw peaks obtained from the measurements with the T7 promoter platform (BBa_K731700). (B) mVenus raw peaks obtained with the tac promoter platform (BBa_K731710). The samples were left overnight in the refrigerator, allowing fluorescence stabilization (protein folding and chromophore oxidation Shaner). Note that the X axis of the chart’s right side expresses the days after sonication and not the hours. The same is for the following charts.


EaErRIintimeptac.jpg

FIGURE 2. Ea, Er and RI in time.
Left and right panels show the apparent and raw termination efficiency, respectively. The bottom chart represents the increase in mCherry expression compared to the control construct without intervening terminator. Data from BBa_K731710 measurements.

While raw peaks are quite variable, especially with the control construct, the termination efficiencies are stable in time. Both the mCherry raw emission and the relative increase in its expression is more variable than mVenus relative quantities. We saw this in all our experiments but we have no explanation to this at all. We tested the consequences of the O.D. equalization additional step measuring cultures which O.D.s were and were not equalized before induction,

ODequalized or not all.jpg

FIGURE 3. Comparison between results obtained equalizing or not cultures' O.D.s before induction
The chart shows Er, RI and Ea kinetics obtained equalizing or not the coltures' O.D.s before induction. These data are calculated from measurements with BBa_K731700 (the T7 promoter platform).

From the data represented above we derived two main conclusions:

  • the results seem to stabilize well 13 hours after sonication, while before that time their variability is still considerable.
  • as we could expect, the O.D.s equalization step decrease the variability in Er and RI, while has less influence on Ea.

Moreover, it is evident a higher variability in data obtained with the T7 terminator, if compared with those obtained with the E. coli terminator. We report this observation, but can’t explain it.


Conclusion.

According to our results, the minor standard deviation is achieved exciting mVenus at 485 nm and measuring mCherry emission at 615 nm; sonicating the sample, incubating at 4°C and taking measurements about 13 hours later. After that, the results seem stable for several days .

"You can sonicate the evening before holidays, and measure when you come back" [Giaco the dwarf]

All the measurements were taken in quadruplicate (4 sonicated samples from the same culture), and repeated the next day. We limited our analysis on two fluorescent proteins, two promoters and two terminators; many other combination could be tested.

References