Difference between revisions of "Part:BBa K1033910"

(Characterization: NWU-China 2019)
Line 17: Line 17:
  
  
<!-- Uncomment this to enable Functional Parameter display
+
 
===Functional Parameters===
+
 
<partinfo>BBa_K1033910 parameters</partinfo>
+
 
<!-- -->
+
  
  
Line 35: Line 34:
 
When we used the microplate reader to measure the excitation light and absorbed light, we found that the spectrum of fwYellow is too narrow. Due to the low precision of the instrument, it is impossible to accurately measure its excitation light and emission light. The excitation light is around 522 nm and the emission is about 536 nm.
 
When we used the microplate reader to measure the excitation light and absorbed light, we found that the spectrum of fwYellow is too narrow. Due to the low precision of the instrument, it is impossible to accurately measure its excitation light and emission light. The excitation light is around 522 nm and the emission is about 536 nm.
  
;
+
 
 +
==Functional Parameters: Austin_UTexas==
 +
<html>
 +
<body>
 +
<partinfo>BBa_K1033910 parameters</partinfo>
 +
<h3><center>Burden Imposed by this Part:</center></h3>
 +
<figure>
 +
<div class = "center">
 +
<center><img src = "https://static.igem.org/mediawiki/parts/f/fa/T--Austin_Utexas--no_burden_icon.png" style = "width:160px;height:120px"></center>
 +
</div>
 +
<figcaption><center><b>Burden Value: 0.2 ± 2.4% </b></center></figcaption>
 +
</figure>
 +
<p> Burden is the percent reduction in the growth rate of <i>E. coli</i> cells transformed with a plasmid containing this BioBrick (± values are 95% confidence limits). This BioBrick did not exhibit a burden that was significantly greater than zero (i.e., it appears to have little to no impact on growth). Therefore, users can depend on this part to remain stable for many bacterial cell divisions and in large culture volumes. Refer to any one of the
 +
<a href="https://parts.igem.org/Part:BBa_K3174002">BBa_K3174002</a> - <a href="https://parts.igem.org/Part:BBa_K3174007">BBa_K3174007</a> pages for more information on the methods, an explanation of the sources of burden,  and other conclusions from a large-scale measurement project conducted by the <a href="http://2019.igem.org/Team:Austin_UTexas">2019 Austin_UTexas team</a>.</p>
 +
<p>This functional parameter was added by the <a href="https://2020.igem.org/Team:Austin_UTexas/Contribution">2020 Austin_UTexas team.</a></p>
 +
</body>
 +
</html>

Revision as of 03:28, 26 August 2020

fwYellow, yellow chromoprotein

This chromoprotein (also known as FezziwigYFP) naturally exhibits strong color when expressed. Compared to many other chromoproteins, such as amilCP (BBa_K592009), amilGFP (BBa_K592010), spisPink (BBa_K1033932), asPink (BBa_K1033933) and aeBlue (BBa_K864401), the color development is slower. The color is readily observed in both LB or on agar plates after 24-64 hours of incubation.

Usage and Biology

This part is useful as a reporter.

Uppsala2013 chromoproteins.JPG

iGEM13_Uppsala: Expression of chromoproteins. The images above show E coli constitutively expressing meffRed BBa_K1033922, aeBlue BBa_K1033929, tsPurple BBa_K1033905, asPink (asCP) BBa_K1033927, fwYellow BBa_K1033910, meffBlue BBa_K1033902, meffRed BBa_K1033922 and scOrange BBa_K1033913.


Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal AgeI site found at 109
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal SapI.rc site found at 486




Characterization: NWU-China 2019

The NWU-China team overexpressed fwYellow protein in E. coli and extracted and purified. The maximum absorbance was measured in a 96-well plate using a microplate reader (Synergy 2).

fwYellow spectum.
Figure 1. fwYellow absorbance spectrum


At the same time, fwYellow can emit strong fluorescence under blue light excitation.

fluorescence of fwYellow.
Figure 1. under blue light excitation, The left one is fwYellow


When we used the microplate reader to measure the excitation light and absorbed light, we found that the spectrum of fwYellow is too narrow. Due to the low precision of the instrument, it is impossible to accurately measure its excitation light and emission light. The excitation light is around 522 nm and the emission is about 536 nm.


Functional Parameters: Austin_UTexas

BBa_K1033910 parameters

Burden Imposed by this Part:

Burden Value: 0.2 ± 2.4%

Burden is the percent reduction in the growth rate of E. coli cells transformed with a plasmid containing this BioBrick (± values are 95% confidence limits). This BioBrick did not exhibit a burden that was significantly greater than zero (i.e., it appears to have little to no impact on growth). Therefore, users can depend on this part to remain stable for many bacterial cell divisions and in large culture volumes. Refer to any one of the BBa_K3174002 - BBa_K3174007 pages for more information on the methods, an explanation of the sources of burden, and other conclusions from a large-scale measurement project conducted by the 2019 Austin_UTexas team.

This functional parameter was added by the 2020 Austin_UTexas team.