Difference between revisions of "Part:BBa J23112:Experience"

 
(3 intermediate revisions by 2 users not shown)
Line 40: Line 40:
 
<!-- End of the user review template -->
 
<!-- End of the user review template -->
 
<!-- DON'T DELETE --><partinfo>BBa_J23112 EndReviews</partinfo>
 
<!-- DON'T DELETE --><partinfo>BBa_J23112 EndReviews</partinfo>
 +
 
{|width='80%' style='border:1px solid gray'
 
{|width='80%' style='border:1px solid gray'
 
|-
 
|-
Line 60: Line 61:
 
As mentioned before, both datasets were collected by methods which produce data at different points after the gene expression. Quantitative real time PCR measures the amount of expressed mRNA while relative fluorescence measurements quantify on protein level. In perspective of stability and half-life periods of mRNA and proteins or due to protein modification, it is comprehensible to obtain varying data-sets and expression rates. Another problem that occurred during our quantitative real-time measurements was the deviation in some of biological replicates. This problem was also observed in another group’s experiments ([http://www.jbioleng.org/content/3/1/4 Kelly et al., 2009]). They mentioned variations across experimental conditions in the absolute activity of the BioBricks. To reduce variation in promoter activity, they measured the activity of promoters relative to BBa_J23101. Furthermore, the iGEM [https://parts.igem.org/wiki/index.php/Part:BBa_J23109 team of Groningen] which participated in 2009 also measured the relative fluorescence of TG1 strain with the promoters J23100, J23109 and J23106 via Relative Promoter Units (RPUs). Their values indicated the comparable tendency to our documented values <br>
 
As mentioned before, both datasets were collected by methods which produce data at different points after the gene expression. Quantitative real time PCR measures the amount of expressed mRNA while relative fluorescence measurements quantify on protein level. In perspective of stability and half-life periods of mRNA and proteins or due to protein modification, it is comprehensible to obtain varying data-sets and expression rates. Another problem that occurred during our quantitative real-time measurements was the deviation in some of biological replicates. This problem was also observed in another group’s experiments ([http://www.jbioleng.org/content/3/1/4 Kelly et al., 2009]). They mentioned variations across experimental conditions in the absolute activity of the BioBricks. To reduce variation in promoter activity, they measured the activity of promoters relative to BBa_J23101. Furthermore, the iGEM [https://parts.igem.org/wiki/index.php/Part:BBa_J23109 team of Groningen] which participated in 2009 also measured the relative fluorescence of TG1 strain with the promoters J23100, J23109 and J23106 via Relative Promoter Units (RPUs). Their values indicated the comparable tendency to our documented values <br>
 
For a more detailed description of our results [http://2012.igem.org/Team:Goettingen/Notebook/Results click here].
 
For a more detailed description of our results [http://2012.igem.org/Team:Goettingen/Notebook/Results click here].
 +
 +
|}
 +
----
 +
 +
{|width='80%' style='border:1px solid gray'
 +
|-
 +
|width='10%'|
 +
<I>[http://2019.igem.org/Team:Tacoma_RAINmakers Tacoma RAINmakers 2019]</i>
 +
|width='60%' valign='top'|
  
 
<br><br>
 
<br><br>
Line 82: Line 92:
 
</html>
 
</html>
  
 +
|}
 +
----
  
 
|}
 
|}
 +
 +
 +
{|width='100%' style='border:1px solid gray'
 +
|-
 +
|width='10%'|
 +
<partinfo>BBa_J23100 AddReview 5</partinfo>
 +
<I>University of Texas at Austin iGEM 2019</I>
 +
|width='60%' valign='top'|
 +
 +
<h3>UT Austin iGEM 2019: Characterization of metabolic burden of the Anderson Series</h3>
 +
 +
<h4>Description</h4>
 +
The 2019 UT Austin iGEM team transformed the Anderson Series promoters into our 'burden monitor' DH10B strain of E. coli, which contains a constitutive GFP cassette in the genome of the cell. GFP expression fluctuates depending on the number of ribosomes available. Using this strain, we characterized the relative burden (percent reduction in growth rate) of each Anderson Series part. Our results showed a range of growth rate reductions for each of these parts due to ribosomal reallocation from the genome of the host cell, towards the expression of RFP. Anderson Series parts with strong promoters are depicted with darker red colors and Anderson Series parts with weak promoters are depicted with lighter pink colors to show relative RFP expression.
 +
We saw a positive correlation between relative promoter strength and metabolic burden; parts with stronger promoters expressed less GFP and had a lower growth rate than parts with weaker promoters. The regression line for the graph below was constructed by measuring the burden of 5 parts that were created by the 2019 UT Austin iGEM team that each contained an Anderson Series promoter (<partinfo>J23104</partinfo> or <partinfo>J23110</partinfo>), an RBS of varying strength, and a BFP reporter. For more information on characterization of these parts through the burden monitor, visit our team’s wiki page: [https://https://2019.igem.org/Team:Austin_UTexas]
 +
 +
<html>
 +
<figure>
 +
<div class = "left">
 +
<img src = "https://static.igem.org/mediawiki/parts/a/a0/AndersonCharacterization.jpg" style = "width:550px;height:500px">
 +
</div>
 +
<figcaption><b>Fig.1:</b>Growth vs GFP Expression graph showing the relative burden positions of the Anderson Series promoters. The parts with strong promoters are depicted in dark red and are clustered near the bottom of the graph because they have lower growth rates and express lower levels of GFP as a result of high cellular burden. The parts with weaker promoter are depicted in light pink ad are clustered near the top of the graph because they have higher growth rates and express higher levels of GFP as a result of low cellular burden.</figcaption>
 +
</figure>
 +
</html>
 +
<br><br>
 +
<html>
 +
<figure>
 +
<div class = "left">
 +
<img src = "https://static.igem.org/mediawiki/parts/8/80/T--Austin_Utexas--andersontable.png" style = "width:545px;height:375px">
 +
</div>
 +
<figcaption><b>Table.1:</b> Burden measurements for the Anderson Series promoters measured as percent reduction in growth rate ± 95% confidence interval. </figcaption>
 +
</figure>
 +
</html>
 +
 +
<h4>Importance of Characterizing Burden</h4>
 +
<p> Although often we cannot avoid using a specific burdensome part, knowing in advance that it is burdensome, and that it has a high chance of mutating into a non-functional genetic device, can help with troubleshooting and coming up with alternatives. In the specific case of fluorescent protein-expressing devices, Fluorescence-activated cell sorting (FACS) can be used to filter out individual cells that meet a certain fluorescence threshold. This way, the cells expressing lower levels of the fluorescent protein are weeded out of the population.</p>

Latest revision as of 20:14, 21 October 2019

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_J23112

Use of this promoter by team Glasgow 2014

We found this promoter is actually identical in sequence to BBa_J23103

BBa_J23116, BBa_J23106, BBa_J23103, and BBa_J23112 were used to express motA and motB together in our composite biobricks:
BBa_ K1463773, BBa_ K1463772, BBa_ K1463770, and BBa_ K1463771 respectively.
These composite biobricks were used to complement the swimming defect of a motA E. coli mutant.
We found that swimming was restored in the following order:
BBa_J23116 > BBa_J23106 > BBa_J23103 = BBa_J23112.
Examination of the sequences of BBa_J23103 and BBa_J23112 showed that they are identical, despite showing different levels of RFP expression in their initial characterisation!

>BBa_J23103 Part-only sequence (35 bp) ctgatagctagctcagtcctagggattatgctagc

>BBa_J23112 Part-only sequence (35 bp) ctgatagctagctcagtcctagggattatgctagc

User Reviews

UNIQ3043bd944030ebdb-partinfo-00000000-QINU UNIQ3043bd944030ebdb-partinfo-00000001-QINU

•••••

for iGEM-Team Goettingen 2012

Characterization experiment by qrtPCR on BBa_J23100, BBa_J23104, BBa_J23105, BBa_J23106, BBa_J23109, BBa_J23112, BBa_J23113, BBa_J23114 by iGEM Team Göttingen (by C. Krüger and J. Kampf)

Description

We used quantitative real-time PCR as a powerful tool for quantification of gene expression. We used this method to examine the expression rate of the Tar receptor gene under control of promoters from the Anderson family of the parts registry. The BioBricks (K777001-K777008) we used for this experiment can be found here.

The reported activities of these promoters are given as the relative fluorescence of these plasmids in strain TG1 [1]. Promoter constructs were cloned into the vector pSB1C3 and expressed in E.coli BL21DE3 grown in LB-media (lysogeny broth). The measurements were performed for each construct and reference as a triplet. Additionally, we included H2O as negative control to predict possible contamination. For the evaluation of our results, the 2–ΔΔCT (Livak) method was applied. We used the weakest promoter with the lowest expression rate as calibrator for the calculations and as reference the housekeeping gene rrsD of E.coli. You can find detailed information of the qrtPCR approach [http://2012.igem.org/Team:Goettingen/Project/Methods#-.3E_Experimental_design here].


Results & Discussion
Comparison of relative expression rates of constitutive promoters by qrtPCR and relative fluorescence (see parts registry,Anderson family). The blue bar indicates the measured expression rates for our constructs (J23100, J23104, J23105, J23106, J23109, J23112, J23113, J23114) and the red ones those for the literature values represented in the “parts registry”. The measurements are illustrated in a logarithmic application. The standard variation was calculated for our measured values (black error bar).

As mentioned before, both datasets were collected by methods which produce data at different points after the gene expression. Quantitative real time PCR measures the amount of expressed mRNA while relative fluorescence measurements quantify on protein level. In perspective of stability and half-life periods of mRNA and proteins or due to protein modification, it is comprehensible to obtain varying data-sets and expression rates. Another problem that occurred during our quantitative real-time measurements was the deviation in some of biological replicates. This problem was also observed in another group’s experiments ([http://www.jbioleng.org/content/3/1/4 Kelly et al., 2009]). They mentioned variations across experimental conditions in the absolute activity of the BioBricks. To reduce variation in promoter activity, they measured the activity of promoters relative to BBa_J23101. Furthermore, the iGEM team of Groningen which participated in 2009 also measured the relative fluorescence of TG1 strain with the promoters J23100, J23109 and J23106 via Relative Promoter Units (RPUs). Their values indicated the comparable tendency to our documented values
For a more detailed description of our results [http://2012.igem.org/Team:Goettingen/Notebook/Results click here].


[http://2019.igem.org/Team:Tacoma_RAINmakers Tacoma RAINmakers 2019]



Tacoma RAINmakers 2019: Relative Strength of Anderson Promoters

We collected characterization data on the relative RFP expression rates of Anderson Promoters BBa_J23100, BBa_J23101, BBa_J23102, BBa_J23105, BBa_J23106, and BBa_J23112 in the RFP expression plasmid BBa_J61002 (samples provided in the 2019 iGEM Distribution Kit).

As our team did not have access to calibration standards such as Texas Red or Rhodamine B, this data was analyzed relative to BBa_J23100 expression. The comparison against BBa_J23100 is consistent with the original Anderson characterization.

When analyzing arbitrary fluorescence units (AFU), we found that our data was comparable to that collected by the Anderson Lab after 3 hours of growth. BBa_J23100 showed the strongest expression followed by BBa_J23102, BBa_J23101, BBa_J23106, BBa_J23105, and BBa_J23112 showing the weakest expression. At hour 5, our data presented a slightly different order of strength. There was increased expression of BBa_J23101 over BBa_J23102. However, after normalizing the data against BBa_J23100, the expression levels of BBa_J23101 and BBa_J23102 were comparable. The OD660 values were still increasing from 3HR and 5HR, which indicates the cultures were still growing. Allowing the cultures to grow further would allow us a better determination regarding the difference in promoter strength of BBa_J23101 and BBa_J23102.

Additional data can be found on our wiki

HTML img Tag


|}


•••••

University of Texas at Austin iGEM 2019

UT Austin iGEM 2019: Characterization of metabolic burden of the Anderson Series

Description

The 2019 UT Austin iGEM team transformed the Anderson Series promoters into our 'burden monitor' DH10B strain of E. coli, which contains a constitutive GFP cassette in the genome of the cell. GFP expression fluctuates depending on the number of ribosomes available. Using this strain, we characterized the relative burden (percent reduction in growth rate) of each Anderson Series part. Our results showed a range of growth rate reductions for each of these parts due to ribosomal reallocation from the genome of the host cell, towards the expression of RFP. Anderson Series parts with strong promoters are depicted with darker red colors and Anderson Series parts with weak promoters are depicted with lighter pink colors to show relative RFP expression. We saw a positive correlation between relative promoter strength and metabolic burden; parts with stronger promoters expressed less GFP and had a lower growth rate than parts with weaker promoters. The regression line for the graph below was constructed by measuring the burden of 5 parts that were created by the 2019 UT Austin iGEM team that each contained an Anderson Series promoter (BBa_J23104 or BBa_J23110), an RBS of varying strength, and a BFP reporter. For more information on characterization of these parts through the burden monitor, visit our team’s wiki page: [2]

Fig.1:Growth vs GFP Expression graph showing the relative burden positions of the Anderson Series promoters. The parts with strong promoters are depicted in dark red and are clustered near the bottom of the graph because they have lower growth rates and express lower levels of GFP as a result of high cellular burden. The parts with weaker promoter are depicted in light pink ad are clustered near the top of the graph because they have higher growth rates and express higher levels of GFP as a result of low cellular burden.


Table.1: Burden measurements for the Anderson Series promoters measured as percent reduction in growth rate ± 95% confidence interval.

Importance of Characterizing Burden

Although often we cannot avoid using a specific burdensome part, knowing in advance that it is burdensome, and that it has a high chance of mutating into a non-functional genetic device, can help with troubleshooting and coming up with alternatives. In the specific case of fluorescent protein-expressing devices, Fluorescence-activated cell sorting (FACS) can be used to filter out individual cells that meet a certain fluorescence threshold. This way, the cells expressing lower levels of the fluorescent protein are weeded out of the population.