Difference between revisions of "Part:BBa E0840:Experience"
Mctastolfi (Talk | contribs) (→User Reviews) |
Mctastolfi (Talk | contribs) (→User Reviews) |
||
Line 30: | Line 30: | ||
Fluorescence can be observed in bacteria exposed to small concentrations, as 0.01µg/ml and 0.02µg/ml, but has low intensity. Fluorescence levels presents medium intensity in the higher concentration as consequence of cell death. Fluorescence intensity increased more than 480% in 0.2µg/ml concentrations, compared to fluorescence intensity from 1µg/ml, even in cell growth reduction, demonstrating its efficiency to induce mer promoter. | Fluorescence can be observed in bacteria exposed to small concentrations, as 0.01µg/ml and 0.02µg/ml, but has low intensity. Fluorescence levels presents medium intensity in the higher concentration as consequence of cell death. Fluorescence intensity increased more than 480% in 0.2µg/ml concentrations, compared to fluorescence intensity from 1µg/ml, even in cell growth reduction, demonstrating its efficiency to induce mer promoter. | ||
+ | |||
+ | Check it out our [https://parts.igem.org/Part:BBa_K1355002:Experience Experience BBa_K1355002] in extended version and the [https://parts.igem.org/Part:BBa_K1355002:Design Desing] of the Hg biosensor! | ||
|} | |} | ||
<!-- End of the user review template --> | <!-- End of the user review template --> |
Revision as of 23:06, 17 October 2014
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_E0840
BBa_E0840 is commonly used to quantify the function of transcriptional control devices.
igem2010 UT-Tokyo
We made an inverted version of this part, BBa_K313007, with the use of PCR.
GFP in the reverse direction are especially useful as outputs of genetic switches in which the coding regions of GFP are inverted by the recombinases.
User Reviews
•••••
UFAM_Brazil 2014 |
We used this biobrick part to build a Hg biosensor! This part worked so well! The graph represented on Figure 1 shows the fluorescence emitted by DH5-alpha transformed with BBa_K1355002 induced by different Hg concentrations in function of the time: Figure 1. GFP fluorescence intensity in the four given times, at mercury chloride concentrations of 0 µg/ml, 0.01 µg/ml, 0.02 µg/ml, 0.1 µg/ml, 0.2 µg/ml, and 1 µg/ml. Fluorescence can be observed in bacteria exposed to small concentrations, as 0.01µg/ml and 0.02µg/ml, but has low intensity. Fluorescence levels presents medium intensity in the higher concentration as consequence of cell death. Fluorescence intensity increased more than 480% in 0.2µg/ml concentrations, compared to fluorescence intensity from 1µg/ml, even in cell growth reduction, demonstrating its efficiency to induce mer promoter. Check it out our Experience BBa_K1355002 in extended version and the Desing of the Hg biosensor! |
••••
Smelissali |
Very visible even without UV excitation on plate and in solution after 24 hours incubation. Not as visible as Part:BBa_I13521 (mRFP), however. |
••••• |
BBa_E0840 was successfully used to quantify the behavior of BBa_R0040, BBa_J45992 and BBa_J45994. |
•••••
Aberdeen_Scotland 2009 |
Our miniprep, double and single digests worked as expected. We used this biobrick for building two of our parts (BBa_K182100 and 'BBa_K182101). We experienced very satisfactory cloning with high efficiency of transformants. The sequencing was correct. We discovered that all the bacteria containing this biobrick were releasing fluorescence even though there was no promoter upstream. The level of fluorescence observed was dependent on the plasmid copy number. We noticed that colonies displayed a visible, yellow-green colour, therefore selection was very easy. |
UNIQ0299342b7b14bfcf-partinfo-0000000B-QINU
Characterization
Transcriptional control of GFP generator
All three transcriptional control devices were quantified using BBa_E0840.