Composite

Part:BBa_K1333309:Experience

Designed by: Runwen Yao   Group: iGEM14_SYSU-China   (2014-09-24)

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K1333309

Improve the function OR characterization of a previously existing BioBrick Part or Device (created by another team, or by your own team in in a previous year of iGEM), and enter this information in the part's page on the Registry. Please see the Registry Contribution help page for help on documenting a contribution to an existing part. This part must not come from your team's 2015 range of part numbers.

User Reviews

UNIQf583e33929ab57c3-partinfo-00000000-QINU UNIQf583e33929ab57c3-partinfo-00000001-QINU We confirmed the function of BBa_K1333309.

Experience by iGEM15_Tokyo_Tech

Introduction

Temperature increase is required for an RNA thermometer in the enhanced expression of BBa_K1333309 (J23119_K115002_E1010) constructed by iGEM 2014 SYSU-China. The RNA thermometers are located in the 5’-untranslated region (5’-UTR) and block the Shine-Dalgarno (SD) sequence by base pairing. Translation initiating temperature allows the disconnection of the coupling of the hydrogen bonds, which block the SD sequence at low temperature. Therefore, RNA thermometers change their conformations to the open state so that the ribosome could access the SD sequence and to initiate translation.
We improved characterization of BBa_K1333309 by (1) measuring the function of the part at 42 ºC, (2) explicating the way to deal with the background derived from Negative control, (3) measuring with the flow cytometer.

Assay protocol

1. Prepare 2 over night cultures for each sample in 3 mL LB medium containing chloramphenicol (25 microg / mL) at 37ºC for 12 h.
2. Dilute the overnight cultures to 1/100 in fresh LB medium (3 mL) containing chloramphenicol (25 microg / mL ) in triplicate (fresh culture).
3. Incubate the triplicated fresh cultures each at 30ºC,37ºC and 42ºC for each sample for 8 h.
4. Centrifuge the samples at 9000x g, 1 min, 4ºC.
5. Remove the supernatants by using P100 pipette and suspend the samples with 1 mL of filtered PBS (phosphate-buffered saline).
6. Dispense all of each suspension into a disposable tube through a cell strainer.
7. Measure fluorescence intensity with flow cytometer.

Results

We measured each sample at 30ºC, 37ºC and 42ºC. The translation initiating temperature is 37ºC. Little background from medium affect results for flow cytometer. Although iGEM 2014 SYSU-China confirmed the function of Pcon_RNA thermometer_rfp at these temperatures, we additionally measured each sample at 42ºC, which is higher than the translation initiating temperature.

The fluorescence intensities of RFP

We found that the fluorescence intensities of both Pcon_RNA thermometer_rfp and Plac_rfp increased along with the rise of the temperature (Fig. 1).

Fig.1.RAW data

The error bar represents the standard deviation of two samples which derived from two different colonies, respectively.

The standardized fluorescence intensities of RFP
The standardized fluorescence intensities of RFP

We obtained increasing ratios of fluorescence intensities at 37ºC and at 42ºC by dividing the each of the raw fluorescence intensities (Fig. 1) by those at 30ºC. The increasing ratios of the Plac_rfp at 37ºC and 42ºC show that the fluorescence intensities, even without the RNA thermometer, increased dependent on temperature. We further evaluated the increasing ratios of Pcon_RNA thermometer_rfp at 37ºC and 42ºC. Compared to the increasing ratios of Plac_rfp, those of the Pcon_RNA thermometer_rfp were higher at respective temperatures. This comparison shows not only the increase in the fluorescence intensities dependent on temperature, (Fig. 1) but also the increase in the fluorescence intensities due to the function of the RNA thermometer (Table. 1). The increasing ratio of Pcon_RNA thermometer_rfp was 1.3 times higher than that of Plac_rfp at 37ºC. Furthermore, the increasing ratio of Pcon_RNA thermometer_rfp was 3.2 times higher than that of Plac_rfp at 42ºC. These differences of the increasing ratios were dependent on the function of the RNA thermometer. We concluded that the RNA thermometer shows higher function at 42ºC compared to 37ºC.

Table.1.The increasing ratios

The standardized fluorescence intensities of RFP after subtracting the background derived from the Negative control cell

In this section, we obtained processed fluorescence intensities by subtracting the fluorescence intensity of a negative control, the RNA thermometer_rfp (Fig. 1) from both the fluorescence intensities of Plac_rfp and Pcon_RNA thermometer_rfp (Fig. 1), each at the same temperature. We then obtained increasing ratios with background subtraction at 37ºC and at 42ºC by dividing the each of the processed fluorescence intensities by those at 30ºC (Table. 2). he increasing ratios of the Plac_rfp with background subtraction at 37ºC and at 42ºC show that the fluorescence intensities increased dependently on temperature. We evaluated the increasing ratios of Pcon_RNA thermometer_rfp with background subtraction at 37ºC and at 42ºC. Compared to the increasing ratios of Plac_rfp with background subtraction, those of the Pcon_RNA thermometer_rfp were higher at respective temperatures. We observed again the increase in the fluorescence intensities due to the function of the RNA thermometer (Table. 2). The increasing ratio of Pcon_RNA thermometer_rfp at 37ºC with background subtraction was 2.6 times higher than that of Plac_rfp at 37ºC. Furthermore, the increasing ratio of Pcon_RNA thermometer_rfp with background subtraction was 6.8 times higher than that of Plac_rfp at 42ºC. These differences in the increasing ratios were dependent on the function of the RNA thermometer. We concluded that the RNA thermometer shows higher function at 42ºC compared to 37ºC.

Table.2.The increasing ratios with background subtraction

Discussion

We examined that the reason the function of the RNA thermometer was worse at 37ºC than at 42ºC was that the amount of hydrogen bonds forming RNA thermometer was not enough to change in the structure of the RNA thermometer at 37ºC.
Furthermore, differences between the increasing ratios with and without background subtraction disclose the importance of background treatment. At 30ºC, Pcon_RNA thermometer_rfp wasn’t translated enough and showed little expression of RFP. Since the fluorescence intensity of Pcon_RNA thermometer_rfp at 30ºC was small, the increasing ratios of the Pcon_RNA thermometer with and without background subtraction greatly differ in both 37ºC and 42ºC (Table. 3). Therefore, it is important to clarify whether the background derived from Negative control was processed or not.

Table.3.The difference the increasing ratios with and without background subtraction

For more information, see [http://2015.igem.org/Team:Tokyo_Tech/Experiment/RNA_thermometer_assay our work in Tokyo_Tech 2015 wiki].