Coding

Part:BBa_K3503006

Designed by: LEONG WENG I   Group: iGEM20_PuiChing_Macau   (2020-10-21)
Revision as of 21:57, 27 October 2020 by Leoseak2 (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)


mfp5-SR-His

This is a composite part designed to improve the fire retardancy with mussel adhesion protein K3089023. The protein sequence in this part is based on the K1608000 sequence from MingDao 2015 Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal BglII site found at 1417
    Illegal BglII site found at 1486
    Illegal BglII site found at 1603
    Illegal BamHI site found at 499
    Illegal BamHI site found at 727
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]


Successful expression of K3503006

In order to validate the protein expression of K1608000, K3503006 and K3503004, we performed SDS-PAGE (coomassie blue staining) and Western blot analysis. To make K3503001, K3503007 and K3503008 easily detectable via Western Blot, we designed our constructs to include a “His tag” which is targeted by a commercially available antibody. With the SDS-PAGE and western blot (anti-his for his-tagged protein), we found successful expression of K1608000, K3503006 and K3503004
Before performing the SDS-PAGE, we grew up our engineered E. coli cells containing a plasmid with K1608000, K3503006 and K3503004 under control of the T7 promoter. Cells were induced with0.1mM IPTG until either OD0.4 (wavelength: 600nm) at 30°C. After expression, cells were then lysed according to our protein extraction protocol, and supernatant and pellet were collected for the SDS-PAGE.

For more experimental details of the Western Blot and SDS-PAGE, please see protocol.

(a) Coomassie blue staining

(b) Western Blot

Figure 1. Western Blot results of inducible expression of K1608000, K3503006, K3503004
  • Lane1: Bio rad protein dual color ladder;
  • Lane2: pet11a
  • Lane3: SR(K1608000)
  • Lane4:SR(K1608000) with 1mM IPTG induction
  • Lane5: K3503006(mfp5-SR)
  • Lane6: K3503006(mfp5-SR) with 1mM IPTG induction
  • Lane7: K3503004(CBD-SR)
  • Lane8: K3503004(CBD-SR) with 1mM IPTG induction

Fire retardant test of K3503006

The test subject was in the size of bed sheet in 300*130mm and the average Moisture content% is 13.55%-14.37%. As demonstrated on Fig 3, all of our engineered flame retardant displayed an improvement compared with the water control.

Figure 2. Vertical Burning Test using bedsheet.
Figure 3. Flame retardancy test using wood.

As demonstrated in Fig 3, all of our engineered K3503001, K3503007 and K3507008 flame retardants displayed an improvement compared with the water control.

[edit]
Categories
Parameters
None