Difference between revisions of "Part:BBa K4165255"
Line 46: | Line 46: | ||
better than that of His Trim21 (L) DOC with GAT COH TD28Rev as the concentration of elution of His | better than that of His Trim21 (L) DOC with GAT COH TD28Rev as the concentration of elution of His | ||
Trim21 (L) DOC with GST COH WWW is more than that of His trim21 (L) DOC with GST COH TD28Rev | Trim21 (L) DOC with GST COH WWW is more than that of His trim21 (L) DOC with GST COH TD28Rev | ||
+ | <p style=" font-weight: bold; font-size:14px;"> Pull down assay of Tau aggregates against GST COH WWW and GST COH TD28Rev </p> | ||
+ | <html> | ||
+ | <p><img src="https://static.igem.wiki/teams/4165/wiki/parts-registry/wetlab-results/pull-down-of-tau-against-www-and-td28rev.jpg" style="margin-left:200px;" alt="" width="500" /></p> | ||
+ | </html> | ||
+ | Figure 6. This graph shows the comparison of pull down assay between Tau aggregates with GST COH WWW and | ||
+ | Tau aggregates with GST COH TD28Rev, showing that the interaction between Tau aggregates with GST COH | ||
+ | WWW is better than that of Tau aggregates with GST COH TD28rev as the concentration of elution of Tau | ||
+ | aggregates with GST COH WWW is more than that of Tau aggregates with GST COH TD28Rev | ||
+ | |||
+ | |||
<!-- Uncomment this to enable Functional Parameter display | <!-- Uncomment this to enable Functional Parameter display |
Revision as of 10:23, 12 October 2022
GST-Coh2-G4S- TD28REV
Long description
Sequence and Features
Assembly Compatibility:
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000INCOMPATIBLE WITH RFC[1000]Illegal BsaI site found at 689
Illegal SapI.rc site found at 85
WetLab Results
Transformation of GST COH (L) TD28 Rev in BL-21 using pGS-21a vector
Figure 1. Transformed plate of GST COH (L) TD28 Rev + pGS-21a
Transformation of GST COH (L) TD21 Rev in DH-5 alpha using pJET vector
Figure 2. Transformed plate of GST COH (L) TD28 Rev + pJET
Comparison between chemical lysis and sonication for GST COH TD28 Rev
Figure 3. this graph shows a difference between chemical lysis and sonication for GST COH TD28 Rev, after we had the results we optimized our protocol to use chemical lysis for GST COH (L) TD28 Rev
SDS PAGE of induced and non induced samples of GST COH TD28 Rev
Figure 4. This figure shows the comparison between the induced and non induced samples of GST COH TD28Rev, where well no.2 is the induced sample of GST COH TD28 Rev while well no.6 is the non induced sample of GST COH TD28Rev showing that our protein is induced effectively owing to our right choice of IPTG, time interval and concentration
Pull down assay His Trim (L) DOC against GST COH WWW and GST COH TD28Rev
Figure 5. This graph shows the comparison of pull down assay between His Trim21 (L) DOC with GST COH WWW and GST COH TD28Rev showing that the interaction between His Trim21 (L) DOC and GST COH WWW is better than that of His Trim21 (L) DOC with GAT COH TD28Rev as the concentration of elution of His Trim21 (L) DOC with GST COH WWW is more than that of His trim21 (L) DOC with GST COH TD28Rev
Pull down assay of Tau aggregates against GST COH WWW and GST COH TD28Rev
Figure 6. This graph shows the comparison of pull down assay between Tau aggregates with GST COH WWW and Tau aggregates with GST COH TD28Rev, showing that the interaction between Tau aggregates with GST COH WWW is better than that of Tau aggregates with GST COH TD28rev as the concentration of elution of Tau aggregates with GST COH WWW is more than that of Tau aggregates with GST COH TD28Rev