Difference between revisions of "Part:BBa K4441002"

(Dilutions)
(Usage and Biology)
 
Line 7: Line 7:
  
 
===Usage and Biology===
 
===Usage and Biology===
This is the sequence for the Forward Inner Primer. The FIP consists of a F2 region at the 3'end and a F1c region at the 5'end [2]. The F2 region is complementary to the F2c region of the template sequence. The F1c region is identical to the F1c region of the template sequence [2]. This FIP primer is part of the primer set that detects the WT BRAF: TTACTTACACGCCAAGTCAATCATCCACAGAGACCTCAAGAGTAATAATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGTGAAATCTCGATGGA
+
This is the sequence for the Forward Inner Primer (FIP). The FIP consists of a F2 region at the 3'end and a F1c region at the 5'end [2]. The F2 region is complementary to the F2c region of the template sequence. The F1c region is identical to the F1c region of the template sequence [2]. This FIP primer is part of the primer set that detects the WT BRAF: TTACTTACACGCCAAGTCAATCATCCACAGAGACCTCAAGAGTAATAATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGTGAAATCTCGATGGA
 
GTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGCACCAGAAGTCATCAGAATGCAAGATAAAAATCCATACAGCTTTCAGTCAGATGTATATGCATTTGGAATT
 
GTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGCACCAGAAGTCATCAGAATGCAAGATAAAAATCCATACAGCTTTCAGTCAGATGTATATGCATTTGGAATT
 
GTTCTGTATGAATTGATGACTGGACAGTTACCTTATTCAAACATCAACAACAGGGACCAG
 
GTTCTGTATGAATTGATGACTGGACAGTTACCTTATTCAAACATCAACAACAGGGACCAG

Latest revision as of 05:34, 12 October 2022


BRAF WT FIP

Sequence used in wetlab experiments: ACTGATGGGACCCACTCCATAAGACCTCACAGTAAAAATA is taken from [1]


Usage and Biology

This is the sequence for the Forward Inner Primer (FIP). The FIP consists of a F2 region at the 3'end and a F1c region at the 5'end [2]. The F2 region is complementary to the F2c region of the template sequence. The F1c region is identical to the F1c region of the template sequence [2]. This FIP primer is part of the primer set that detects the WT BRAF: TTACTTACACGCCAAGTCAATCATCCACAGAGACCTCAAGAGTAATAATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGTGAAATCTCGATGGA GTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGCACCAGAAGTCATCAGAATGCAAGATAAAAATCCATACAGCTTTCAGTCAGATGTATATGCATTTGGAATT GTTCTGTATGAATTGATGACTGGACAGTTACCTTATTCAAACATCAACAACAGGGACCAG

Dilutions

Storage Primer Concentration: 100 μM

10X Concentration (Stock): 16 μM

Volume of 10X primer mix: 10 μL

1X Concentration (Final): 1.6 μM

Volume of storage primer needed: 1.6 μL

Mixed with F3, B3, BIP for a total of 3.6 μL -- Final primer mix 1 μL of final primer mix is used in the LAMP reaction mix. For more information, visit https://2022.igem.org/Team:Washington

Citations

1. Du, Y., Pothukuchy, A., Gollihar, J. D., Nourani, A., Li, B., & Ellington, A. D. (2017). Coupling sensitive nucleic acid amplification with commercial pregnancy test strips. Angewandte Chemie International Edition, 56(4), 992-996.

2. Loop mediated isothermal amplification - technote. (n.d.). Retrieved October 11, 2022, from http://www.premierbiosoft.com/tech_notes/Loop-Mediated-Isothermal-Amplification.html Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]