Difference between revisions of "Part:BBa K4438111"

 
Line 4: Line 4:
  
 
FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-30c-D2, after transcription, binds to miR-30c, the transcription product of BBa_K4438503. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.
 
FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-30c-D2, after transcription, binds to miR-30c, the transcription product of BBa_K4438503. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.
 
Usage and Biology
 
This part can be used for the detection of miR-30c, which proves to be a biomarker for many diseases. The ON and OFF structure for the sensor was generated as given:
 
 
 
  
 
<!-- Add more about the biology of this part here
 
<!-- Add more about the biology of this part here
 
===Usage and Biology===
 
===Usage and Biology===
 +
This part can be used for the detection of miR-30c, which proves to be a biomarker for many diseases. The ON and OFF structure for the sensor was generated as given:
  
 
<!-- -->
 
<!-- -->
Line 22: Line 18:
 
<partinfo>BBa_K4438111 parameters</partinfo>
 
<partinfo>BBa_K4438111 parameters</partinfo>
 
<!-- -->
 
<!-- -->
 +
===References===
 +
Huang, K., Doyle, F., Wurz, Z. E., Tenenbaum, S. A., Hammond, R. K., Caplan, J. L., & Meyers, B. C. (2017). FASTmiR: an RNA-based sensor for in vitro quantification and live-cell localization of small RNAs. Nucleic acids research, 45(14), e130-e130

Revision as of 00:14, 12 October 2022


FASTmiR-30c-D2

FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-30c-D2, after transcription, binds to miR-30c, the transcription product of BBa_K4438503. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.

Sequence and Features


Assembly Compatibility:
  • 10
    INCOMPATIBLE WITH RFC[10]
    Illegal SpeI site found at 53
  • 12
    INCOMPATIBLE WITH RFC[12]
    Illegal SpeI site found at 53
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    INCOMPATIBLE WITH RFC[23]
    Illegal SpeI site found at 53
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal SpeI site found at 53
  • 1000
    COMPATIBLE WITH RFC[1000]


References

Huang, K., Doyle, F., Wurz, Z. E., Tenenbaum, S. A., Hammond, R. K., Caplan, J. L., & Meyers, B. C. (2017). FASTmiR: an RNA-based sensor for in vitro quantification and live-cell localization of small RNAs. Nucleic acids research, 45(14), e130-e130