Difference between revisions of "Part:BBa K3725040:Experience"

Line 4: Line 4:
 
<br>
 
<br>
 
<br>
 
<br>
<center>[[File:T--Lambert GA--PhytoIPTGFluorescenceData.png|500px]]</center>
+
<center>[[File:T--Lambert GA--PhytoIPTGFluorescenceData.jpeg|500px]]</center>
 
<br>
 
<br>
 
<center><I>Figure 2: This graph compares the mean fluorescence per optical density values of the P. cryptogea toehold switch, positive control (pUC19), and the dual plasmid. The toehold switch and positive control have very low fluorescence per optical density values, whereas the dual plasmid has a higher fluorescence per optical density value, that is significantly different from the other two groups..</I></center>
 
<center><I>Figure 2: This graph compares the mean fluorescence per optical density values of the P. cryptogea toehold switch, positive control (pUC19), and the dual plasmid. The toehold switch and positive control have very low fluorescence per optical density values, whereas the dual plasmid has a higher fluorescence per optical density value, that is significantly different from the other two groups..</I></center>

Revision as of 02:03, 21 October 2021


The T7 Phytophthora Trigger (Part BBa_K3725040) and the Phytophthora Toehold w/ GFP Reporter (Part BBa_K3725010) are intended to be compatible with each other and used in conjunction. To test the compatibility of the trigger sequence with the toehold sequence, a dual-plasmid transformation was performed, and fluorescence was measured in comparison with cells transformed with only the toehold part and pUC19 (positive control). All samples were divided by optical density to obtain a standardized unit. The fluorescence per optical density unit measurement of cells transformed with both the toehold and trigger sequences was greater and had a statistically significant difference in comparison to cells transformed with only the toehold part and pUC19 plasmid.

500px


Figure 2: This graph compares the mean fluorescence per optical density values of the P. cryptogea toehold switch, positive control (pUC19), and the dual plasmid. The toehold switch and positive control have very low fluorescence per optical density values, whereas the dual plasmid has a higher fluorescence per optical density value, that is significantly different from the other two groups..

Applications of BBa_K3725040

User Reviews

UNIQ6dbc6c37984a3a4e-partinfo-00000000-QINU UNIQ6dbc6c37984a3a4e-partinfo-00000001-QINU