Difference between revisions of "Part:BBa K3733046"

 
Line 7: Line 7:
  
  
<!-- Add more about the biology of this part here
 
 
===Usage and Biology===
 
===Usage and Biology===
 +
<p>This is a composite part constructed to verify the effectiveness of the heat-inducible RNA thermometer.
 +
</p>
  
<!-- -->
+
===Functional Parameters===
<span class='h3bb'>Sequence and Features</span>
+
<p>
 +
We transformed this composite part into <i>E.coli</i> DH5α. We cultured both experimental group and control group at both 37 ℃ and 28 ℃ for 12 hours and detected RFU / OD<sub>600</sub> by a microplate reader. As the result shown in <b>Figure 1</b>, RFU / OD<sub>600</sub> data of the media at 37 ℃ are obviously higher than ones at 28 ℃, which could explain the RNA thermometer is valid.
 +
</p>
 +
 
 +
<html>
 +
<head>
 +
<meta charset="utf-8">
 +
<title>无标题文档</title>
 +
</head>
 +
<body>
 +
<center><img src="https://static.igem.org/mediawiki/parts/9/90/T--HZAU-China-T-ind-comp-1.png" style="width:500px;height:360px"></center>
 +
<center><b>Figure 1. </b> RFU / OD<sub>600</sub> data of the media at 37 ℃ and 28 ℃(heat-inducible RNA thermosensors) </center>
 +
<br>
 +
</body>
 +
</html>
 +
 
 +
===Sequence and Features===
 
<partinfo>BBa_K3733046 SequenceAndFeatures</partinfo>
 
<partinfo>BBa_K3733046 SequenceAndFeatures</partinfo>
  

Revision as of 18:00, 20 October 2021


RNA Thermometer(heat-inducible) test system

Use a constitutive promoter (BBa_J23110), RNA thermometer (BBa_K3247005), strong RBS (BBa_B0034), fluorescent protein neGFP (BBa_K3733012),and an artificial terminator (BBa_B1006). Will express high levels of fluorescent protein above 37 ℃. Source:Used a strong RBS to produce high levels of expression of the neGFP fluorescent protein.


Usage and Biology

This is a composite part constructed to verify the effectiveness of the heat-inducible RNA thermometer.

Functional Parameters

We transformed this composite part into E.coli DH5α. We cultured both experimental group and control group at both 37 ℃ and 28 ℃ for 12 hours and detected RFU / OD600 by a microplate reader. As the result shown in Figure 1, RFU / OD600 data of the media at 37 ℃ are obviously higher than ones at 28 ℃, which could explain the RNA thermometer is valid.

无标题文档

Figure 1. RFU / OD600 data of the media at 37 ℃ and 28 ℃(heat-inducible RNA thermosensors)

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    INCOMPATIBLE WITH RFC[12]
    Illegal NheI site found at 7
    Illegal NheI site found at 30
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal AgeI site found at 158
    Illegal AgeI site found at 281
  • 1000
    COMPATIBLE WITH RFC[1000]