Difference between revisions of "Part:BBa K3503007"
Philip Cheng (Talk | contribs) |
Philip Cheng (Talk | contribs) |
||
Line 59: | Line 59: | ||
<div class="column1"> | <div class="column1"> | ||
<img src="https://2020.igem.org/wiki/images/d/d5/T--Puiching_Macau--alpha_blue.png" style="width:100%"> | <img src="https://2020.igem.org/wiki/images/d/d5/T--Puiching_Macau--alpha_blue.png" style="width:100%"> | ||
+ | <p style="text-align: center">(a) Coomassie blue staining</p> | ||
</div> | </div> | ||
<div class="column1"> | <div class="column1"> | ||
<img src="https://2020.igem.org/wiki/images/9/9d/T--Puiching_Macau--Alpha_western.png" style="width:100%"> | <img src="https://2020.igem.org/wiki/images/9/9d/T--Puiching_Macau--Alpha_western.png" style="width:100%"> | ||
+ | <p style="text-align: center">(b) Western Blot</p> | ||
</div> | </div> | ||
</div> | </div> | ||
</div> | </div> | ||
− | <div class="legend">Figure | + | <div class="legend">Figure 1. Western Blot results of inducible expression of K3503001, K3503007, K3503008 |
<br>(a) | <br>(a) | ||
<ul> | <ul> | ||
Line 80: | Line 82: | ||
<h2>Fire retardant test of K3503007</h2> | <h2>Fire retardant test of K3503007</h2> | ||
− | <p>The test subject was in the size of bed sheet in 300*130mm and the average Moisture content% is 13.55%-14.37%. As demonstrated on Fig | + | <p>The test subject was in the size of bed sheet in 300*130mm and the average Moisture content% is 13.55%-14.37%. As demonstrated on Fig 2, all of our engineered flame retardant displayed a significant improvement compared with the water control.</p> |
<img src="https://2020.igem.org/wiki/images/9/9c/T--Puiching_Macau--bedsheet_chart.png"> | <img src="https://2020.igem.org/wiki/images/9/9c/T--Puiching_Macau--bedsheet_chart.png"> | ||
− | <div class="legend">Figure | + | <div class="legend">Figure 2. Vertical Burning Test using bedsheet. |
<img src="https://2020.igem.org/wiki/images/2/2e/T--Puiching_Macau--wood.png"> | <img src="https://2020.igem.org/wiki/images/2/2e/T--Puiching_Macau--wood.png"> | ||
− | <div class="legend">Figure | + | <div class="legend">Figure 3. Flame retardancy test using wood. |
− | <p>As demonstrated in Fig | + | <p>As demonstrated in Fig 3, all of our engineered K3503001, K3503007 and K3507008 flame retardants displayed a significant improvement compared with the water control. </p> |
</html> | </html> |
Revision as of 20:20, 26 October 2020
mfp5-alpha casein-His
This is a composite part designed to improve the fire retardancy with mussel adhesion protein K3089023. The protein sequence in this part is based on Alpha s1 casein (K2924026)
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21INCOMPATIBLE WITH RFC[21]Illegal BamHI site found at 499
Illegal BamHI site found at 727
Illegal BamHI site found at 1525 - 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]
Successful expression of K3503007
In order to validate the protein expression of K3503001, K3503007 and K3503008, we performed SDS-PAGE (coomassie blue staining) and Western blot analysis. To make K3503001, K3503007 and K3503008 easily detectable via Western Blot, we designed our constructs to include a “His tag” which is targeted by a commercially available antibody. With the SDS-PAGE and western blot (anti-his for his-tagged protein), we found successful expression of K3503001, K3503007 and K3503008.
Before performing the SDS-PAGE, we grew up our engineered E. coli cells containing a plasmid with K3503001, K3503007 and K3503008 under control of the T7 promoter. Cells were induced with0.1mM IPTG until either OD0.4 (wavelength: 600nm) at 30°C. After expression, cells were then lysed according to our protein extraction protocol, and supernatant and pellet were collected for the SDS-PAGE.
(a) Coomassie blue staining
(b) Western Blot
(a)
- Lane1: Bio rad protein dual color ladder;
- Lane2: pet11a
- Lane3: K3503001
- Lane4:K3503001 with 0.1mM IPTG induction
- Lane5: K3503007
- Lane6: K3503007 with 0.1mM IPTG induction
- Lane7: K3503008
- Lane8:K3503008 with 0.1mM IPTG induction
Fire retardant test of K3503007
The test subject was in the size of bed sheet in 300*130mm and the average Moisture content% is 13.55%-14.37%. As demonstrated on Fig 2, all of our engineered flame retardant displayed a significant improvement compared with the water control.
As demonstrated in Fig 3, all of our engineered K3503001, K3503007 and K3507008 flame retardants displayed a significant improvement compared with the water control.