triggers of NIMPLY gate (NIMPLY1)
two input triggers of NIMPLY1 logic gate to perform the truth table
Design
In the NIMPLY gate, a deactivating RNA (INPUT A) uses direct hybridization or strand displacement to abolish trigger RNA (input B) activity. So when only the correct trigger RNA is expressed, the switch can be turned on.
Result
The left figure shows that when INPUT A=0, INPUT B=1, the fluorescence of GFP is high. And the fluorescence intensity of GFP was low in the other three groups. This corresponds to the situation described in the truth table on the right. INPUT A=1 means that aTc (0.25 mg/ml) is added, INPUT B=1 means that HSL (0.1 mg/ml) is added.
Sequence and Features
Assembly Compatibility:
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21INCOMPATIBLE WITH RFC[21]Illegal XhoI site found at 1
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]