Difference between revisions of "Part:BBa K3515006"

 
Line 4: Line 4:
  
 
Synechococcus Phosphate Binding Protein (PiBP) selectively binds inorganic phosphate in its active site, inducing a conformation change in the N and C termini regions, respectively. This makes it a distinguishable candidate for in vivo or in vitro phosphate monitoring using fluorescence resonance energy transfer (FRET). Coupling this protein with two fluorophores can permit phosphate detection. This composite part has coupled PiBP with mNeonGreen in the N-terminus and mCherry in the C-terminus regions as FRET pairs. As PiBP binds phosphate these fluorophores in the two terminal regions come together and energy transfer occurs from donor to acceptor, permitting detection as an increase in intensity is detected. Phosphate detection is vital as phosphate is used in cells for the synthesis of DNA, phospholipids, ATP, and is involved in other signal cascades or post-transcriptional modifications. Phosphate is also a crucial biomarker used in clinical medicine for tracking the progression and status of Chronic Kidney Disease (CKD) patients. As such a biosensor for phosphate tracking may be of great interest to patients and clinicians. This part includes a mutated PiBP to have a cysteine modification that will bind cysteine linker arms and be used for biosensor immobilization allowing the detection of inorganic phosphate. The FRET pair used in this construction were considered especially for physiological detection of phosphate as they have a high intensity and are therefore able to have an expanded dynamic linear range of detection.  
 
Synechococcus Phosphate Binding Protein (PiBP) selectively binds inorganic phosphate in its active site, inducing a conformation change in the N and C termini regions, respectively. This makes it a distinguishable candidate for in vivo or in vitro phosphate monitoring using fluorescence resonance energy transfer (FRET). Coupling this protein with two fluorophores can permit phosphate detection. This composite part has coupled PiBP with mNeonGreen in the N-terminus and mCherry in the C-terminus regions as FRET pairs. As PiBP binds phosphate these fluorophores in the two terminal regions come together and energy transfer occurs from donor to acceptor, permitting detection as an increase in intensity is detected. Phosphate detection is vital as phosphate is used in cells for the synthesis of DNA, phospholipids, ATP, and is involved in other signal cascades or post-transcriptional modifications. Phosphate is also a crucial biomarker used in clinical medicine for tracking the progression and status of Chronic Kidney Disease (CKD) patients. As such a biosensor for phosphate tracking may be of great interest to patients and clinicians. This part includes a mutated PiBP to have a cysteine modification that will bind cysteine linker arms and be used for biosensor immobilization allowing the detection of inorganic phosphate. The FRET pair used in this construction were considered especially for physiological detection of phosphate as they have a high intensity and are therefore able to have an expanded dynamic linear range of detection.  
 +
 +
[[Image:pibpcartoon.png|800px]]
  
 
<!-- Add more about the biology of this part here
 
<!-- Add more about the biology of this part here

Revision as of 14:29, 25 May 2020


Synechococcus Phosphate Binding Protein with cysteine modification(s) and FRET to monitor phosphate

Synechococcus Phosphate Binding Protein (PiBP) selectively binds inorganic phosphate in its active site, inducing a conformation change in the N and C termini regions, respectively. This makes it a distinguishable candidate for in vivo or in vitro phosphate monitoring using fluorescence resonance energy transfer (FRET). Coupling this protein with two fluorophores can permit phosphate detection. This composite part has coupled PiBP with mNeonGreen in the N-terminus and mCherry in the C-terminus regions as FRET pairs. As PiBP binds phosphate these fluorophores in the two terminal regions come together and energy transfer occurs from donor to acceptor, permitting detection as an increase in intensity is detected. Phosphate detection is vital as phosphate is used in cells for the synthesis of DNA, phospholipids, ATP, and is involved in other signal cascades or post-transcriptional modifications. Phosphate is also a crucial biomarker used in clinical medicine for tracking the progression and status of Chronic Kidney Disease (CKD) patients. As such a biosensor for phosphate tracking may be of great interest to patients and clinicians. This part includes a mutated PiBP to have a cysteine modification that will bind cysteine linker arms and be used for biosensor immobilization allowing the detection of inorganic phosphate. The FRET pair used in this construction were considered especially for physiological detection of phosphate as they have a high intensity and are therefore able to have an expanded dynamic linear range of detection.

Pibpcartoon.png

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal BamHI site found at 1539
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal AgeI site found at 1129
  • 1000
    COMPATIBLE WITH RFC[1000]