Difference between revisions of "Part:BBa K3245001"

Line 4: Line 4:
 
<p>This fused promoter is designed for the situation that QS effect and high expression level are required at the same time in a circuit if leakage is acceptable to some extent. We applied this enhanced promoter to improve lacZ expression when bacteria reached a high density. </p>
 
<p>This fused promoter is designed for the situation that QS effect and high expression level are required at the same time in a circuit if leakage is acceptable to some extent. We applied this enhanced promoter to improve lacZ expression when bacteria reached a high density. </p>
 
<h2>Design:</h2>
 
<h2>Design:</h2>
[[File:T--Fudan--Part50.png|700px]]
+
[[File:T--Fudan--Part50.png|500px]]
 
<p>As the figure shows, we substituted the -35 to -10 region of the original promoter luxpR with the one of J23100, a strong constitutive promoter. This region is rarely concerned as it’s rather conservative in promoters with the same function, but it has crucial structural effect on σ factor binding and other events in transcription regulation. Fortunately the change proved to be effective on adjusting the behavior of the regulatory promoter.</p>
 
<p>As the figure shows, we substituted the -35 to -10 region of the original promoter luxpR with the one of J23100, a strong constitutive promoter. This region is rarely concerned as it’s rather conservative in promoters with the same function, but it has crucial structural effect on σ factor binding and other events in transcription regulation. Fortunately the change proved to be effective on adjusting the behavior of the regulatory promoter.</p>
  
Line 15: Line 15:
 
<p>4. Add 100 µl bacteria culture medium into each well of a 96-well plate. One well of LB as blank, one group of wild type DH10B as control.</p>
 
<p>4. Add 100 µl bacteria culture medium into each well of a 96-well plate. One well of LB as blank, one group of wild type DH10B as control.</p>
 
<p>5. Measure OD600 and fluorescence continuously every 30 minutes with a microplate reader.</p>
 
<p>5. Measure OD600 and fluorescence continuously every 30 minutes with a microplate reader.</p>
[[File:T--Fudan--Part51.png|700px]]
+
[[File:T--Fudan--Part51.png|500px]]

Revision as of 05:42, 19 October 2019

BBa_K3245001 luxpR-fus100:

This hybrid promoter has higher expression level when induced by luxR-AHL complex triggered by quorum sensing ( QS ) in some Gram-negative bacteria, meanwhile it’s leakage is also higher when not induced.

Usage and biology:

This fused promoter is designed for the situation that QS effect and high expression level are required at the same time in a circuit if leakage is acceptable to some extent. We applied this enhanced promoter to improve lacZ expression when bacteria reached a high density.

Design:

T--Fudan--Part50.png

As the figure shows, we substituted the -35 to -10 region of the original promoter luxpR with the one of J23100, a strong constitutive promoter. This region is rarely concerned as it’s rather conservative in promoters with the same function, but it has crucial structural effect on σ factor binding and other events in transcription regulation. Fortunately the change proved to be effective on adjusting the behavior of the regulatory promoter.


Characterization:

Measurement Protocol

1. Transform a control plasmid containing luxI and luxR ( all from official parts ) with pUC ori ( high copy number ) and an effect plasmid containing luxpR-fus100 / luxpR-HS100 and GFP behind the promoter with p15A ori (medium copy number ) into DH10B.

2. Pick a single colony by a sterile tip from each of the LB plates for all the experimental and control groups. Add the colony into 3 ml LB with ampicillin at 100 μg/ml. Incubate overnight at 37℃ in a shaker.

3. Measure and keep all groups OD600 reach 1. Inocuate each group with with 1/5000 concentration. Incubate 12 hours at 37℃ in a shaker.

4. Add 100 µl bacteria culture medium into each well of a 96-well plate. One well of LB as blank, one group of wild type DH10B as control.

5. Measure OD600 and fluorescence continuously every 30 minutes with a microplate reader.

T--Fudan--Part51.png