Difference between revisions of "Part:BBa K2572001"

Line 7: Line 7:
 
In our project we characterized its threshold temperature and sensitivity. Downstream gene expression is not detected at 37 degrees Celsius while it is bright at 39 degrees Celsius. This diagrees a little with the work of Piraner et al.(Piraner et al., 2016) which reports the threshold at 41-42 degrees Celsius.
 
In our project we characterized its threshold temperature and sensitivity. Downstream gene expression is not detected at 37 degrees Celsius while it is bright at 39 degrees Celsius. This diagrees a little with the work of Piraner et al.(Piraner et al., 2016) which reports the threshold at 41-42 degrees Celsius.
  
quantitiative data needed
+
https://static.igem.org/mediawiki/2018/4/42/T--RDFZ-China--TSR-Quantitative.png
 +
 
 +
https://static.igem.org/mediawiki/2018/thumb/8/8e/T--RDFZ-China--TSRquali.jpeg/800px-T--RDFZ-China--TSRquali.jpeg
  
 
<!-- Add more about the biology of this part here
 
<!-- Add more about the biology of this part here

Revision as of 03:49, 18 October 2018


Tcl42 thermal sensitive cl repressor

TcI42 is a high-performance thermal bioswitch. It is an upshifted variant of a well-known temperature-sensitive variant of the bacteriophage λ repressor cI (mutant cI857, here referred to as TcI) acting on a tandem pR–pL operator–promoter. The potential utility of these devices in three distinct in vivo scenarios relevant to mammalian microbial therapy is now well demonstrated. These scenarios include spatially selective activation within a mammalian host using focused ultrasound, sensing and response to a fever, and self-destruction at ambient temperatures to prevent environmental contamination after leaving the intended host. This coincides largely with our team’s work.

In our project we characterized its threshold temperature and sensitivity. Downstream gene expression is not detected at 37 degrees Celsius while it is bright at 39 degrees Celsius. This diagrees a little with the work of Piraner et al.(Piraner et al., 2016) which reports the threshold at 41-42 degrees Celsius.

T--RDFZ-China--TSR-Quantitative.png

800px-T--RDFZ-China--TSRquali.jpeg

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]


Reference

D. I. Piraner, A. Farhadi, H. C. Davis, D. Wu, D. Maresca, J. O. Szablowski, M. G. Shapiro, Going deeper: Biomolecular tools for acoustic and magnetic imaging and control of cellular function. Biochemistry 56, 5202–5209 (2017).