Difference between revisions of "Part:BBa K2602024:Experience"

(User Reviews)
 
Line 25: Line 25:
 
</html>
 
</html>
 
===Validation of GFP fluorescence===
 
===Validation of GFP fluorescence===
The experimental setup: Bacteria were grown until an OD600 of 0.2-0.4 in LB-medium and 25 ug/ml chloramphenicol. They where then placed in an 96-well plate in quadruplicates. The OD was measured in the start and the end of the experimental time. Fluorescence was measured every 15 minutes for 16 hours and the temperature was set to 37 degrees celsius. The values shown in fig. 1 are the fluorescence intensity divided by the start OD. Excitation was measured at 485 nm and emission at 520 nm.
+
The experimental setup: Bacteria were grown until an OD600 of 0.2-0.4 in LB-medium and 25 ug/ml chloramphenicol. They were then placed in an 96-well plate in quadruplicates. The OD was measured in the start and the end of the experimental time. Fluorescence was measured every 15 minutes for 16 hours and the temperature was set to 37°C. The values shown in Figure. 1 are the fluorescence intensity divided by the start OD. Excitation was measured at 485 nm and emission at 520 nm.
[[File:T--Linkoping_Sweden--Lund.png|430px|thumb|center|Figure 1. GFP intensity over 16 hours. Error bars represent SD. Total time is 16 hours and fluorescence was measured every 15 minutes.]]
+
[[File:T--Linkoping_Sweden--Lund.png|430px|thumb|center|Figure 1. GFP intensity over 16 hours. Error bars represent Standard Deviation. Total time is 16 hours and fluorescence was measured every 15 minutes.]]

Latest revision as of 21:43, 17 October 2018


This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K2602024

User Reviews

UNIQ24d4411c2692a1ef-partinfo-00000000-QINU UNIQ24d4411c2692a1ef-partinfo-00000001-QINU

2018 iGEM team Linkoping Sweden

2018 iGEM team Linkoping Sweden validated this part.

Validation of GFP fluorescence

The experimental setup: Bacteria were grown until an OD600 of 0.2-0.4 in LB-medium and 25 ug/ml chloramphenicol. They were then placed in an 96-well plate in quadruplicates. The OD was measured in the start and the end of the experimental time. Fluorescence was measured every 15 minutes for 16 hours and the temperature was set to 37°C. The values shown in Figure. 1 are the fluorescence intensity divided by the start OD. Excitation was measured at 485 nm and emission at 520 nm.

Figure 1. GFP intensity over 16 hours. Error bars represent Standard Deviation. Total time is 16 hours and fluorescence was measured every 15 minutes.