Difference between revisions of "Part:BBa K2467002:Experience"
Line 15: | Line 15: | ||
<I>Username</I> | <I>Username</I> | ||
|width='60%' valign='top'| | |width='60%' valign='top'| | ||
− | + | Five different concentrations of NaCl were added to tryptone and yeast extract (same as LB) and E.coli containing the biosensor plasmid and were grown overnight in triplicate. After 18 hours the red fluorescence of 100ul of culture was measured in a TECAN m1000 plate reader set for excitation/emission wavelengths of 584/607nm at a gain of 100. | |
+ | |||
+ | |||
+ | Figure showing fluorescence readings of RFP reporter for ProU consensus promoter. Error bars show standard error of the mean. | ||
+ | |||
+ | These results show that the biosensor is sensitive from at low osmolarity (0-100mM NaCl). At more normal osmolarity (100-400mM NaCl) there is no difference (normal LB is 170mM NaCl). | ||
+ | |||
|}; | |}; | ||
<!-- End of the user review template --> | <!-- End of the user review template --> | ||
<!-- DON'T DELETE --><partinfo>BBa_K2467002 EndReviews</partinfo> | <!-- DON'T DELETE --><partinfo>BBa_K2467002 EndReviews</partinfo> |
Revision as of 17:53, 2 October 2018
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K2467002
User Reviews
UNIQa90c946c47fd5c38-partinfo-00000000-QINU UNIQa90c946c47fd5c38-partinfo-00000001-QINU