Difference between revisions of "Part:BBa K381001"

Line 17: Line 17:
  
 
== NCKU_Tainan 2017 ==
 
== NCKU_Tainan 2017 ==
 
+
BBa_K381001 was first designed by Katharine Coyte from team BCCS-Bristol in iGEM 2010. It is a nitrate reporter, PyeaR-GFP composite. The team BCCS-Bristol only test the BioBrick’s sensitivity at a higher concentration, but the nitrate level of aquatic water usually won’t reach up to 1 mM. Therefore, we carry out experiment by testing the fluorescence intensity with ppm scale of Potassium Nitrate, which is much more lower than all the teams before. The results are shown below.
 +
[[File:Fluorescence intensity-logarithm of nitrate concentration figure.png|450px|centre]]
 +
It shows that the BioBrick BBa_K381001 have nice sensitivity not only in high nitrate concentration, but low concentration as well. Many teams had done improvements of K381001, but our team bring out the most beautiful data. And we also take X axis logarithm, which can make our data linear. Not only easier to read, but also more meaningful.
 
<!-- Add more about the biology of this part here
 
<!-- Add more about the biology of this part here
 
===Usage and Biology===
 
===Usage and Biology===

Revision as of 15:40, 27 October 2017

Nitrate reporter: PyeaR - GFP composite

Nitrate and Nitrite sensitive promoter PyeaR with a GFP coding device and strong RBS to create a nitrate-sensitive system which signals through expression of GFP.

PyeaR is normally repressed by NsrR, a protein native to most 'E. coli' cells. When Nitrate or Nitrite enter the cell it is converted to Nitric Oxide. This binds to NsrR, halting the repression and allowing the production of GFP.

Optimum use appears to be when sensing nitrate within a range of 0 - 20 mM (Calculated from Miller assays)

Activity between 0 - 10mM was investigated using an assay measuring change in GFP expression with increasing levels of Potassium Nitrate, the results of which can be seen below.

GFPChar0to10.png


ParisBettencourt12NitrateReporter.png

Additional characterization. Strain was NEB Turbo.

NCKU_Tainan 2017

BBa_K381001 was first designed by Katharine Coyte from team BCCS-Bristol in iGEM 2010. It is a nitrate reporter, PyeaR-GFP composite. The team BCCS-Bristol only test the BioBrick’s sensitivity at a higher concentration, but the nitrate level of aquatic water usually won’t reach up to 1 mM. Therefore, we carry out experiment by testing the fluorescence intensity with ppm scale of Potassium Nitrate, which is much more lower than all the teams before. The results are shown below.

Fluorescence intensity-logarithm of nitrate concentration figure.png

It shows that the BioBrick BBa_K381001 have nice sensitivity not only in high nitrate concentration, but low concentration as well. Many teams had done improvements of K381001, but our team bring out the most beautiful data. And we also take X axis logarithm, which can make our data linear. Not only easier to read, but also more meaningful. Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal BsaI.rc site found at 773