Difference between revisions of "Help:2017 Competent Cell Test Kit"

(Created page with "{{HelpPage/MainLinks}} {{Help/3AAK_Style}} <html> <table width="100%"> <tr> <td class="headerstep"> Competent Cell Test Kit </td> <td rowspan=2> <img src="http://parts.igem.or...")
 
Line 14: Line 14:
 
<td style="vertical-align: top; padding: 10px;">
 
<td style="vertical-align: top; padding: 10px;">
 
<p>Before using your competent cells in an experiment, use the <b>Competent Cell Test Kit</b> to test the efficiency of your competent cells!</p>
 
<p>Before using your competent cells in an experiment, use the <b>Competent Cell Test Kit</b> to test the efficiency of your competent cells!</p>
<p>The kit includes three vials of purified plasmid DNA from <a href="https://parts.igem.org/Part:BBa_J04450">BBa_J04450</a> (RFP construct) in plasmid backbone pSB1C3. Each vial contains DNA at a different concentration: 100pg/ul, 50pg/ul, 10pg/ul. Perform transformations with each of these to determine how efficient your competent cells are.</p>
+
<p>The kit includes three vials of purified plasmid DNA from <a href="https://parts.igem.org/Part:BBa_J04450">BBa_J04450</a> (RFP construct) in plasmid backbone pSB1C3. Each vial contains DNA at a different concentration: 100 pg/&micro;L, 50 pg/&micro;L, 10 pg/&micro;L. Perform transformations with each of these to determine how efficient your competent cells are.</p>
 
<p><i>Note:</i> Transformations performed with ligation products usually do not yield as many colonies because of the low DNA concentration in the ligation mixture. This means that you may see different results doing this test than you will at the end of the 3A Assembly protocol, or any other ligation.</p>
 
<p><i>Note:</i> Transformations performed with ligation products usually do not yield as many colonies because of the low DNA concentration in the ligation mixture. This means that you may see different results doing this test than you will at the end of the 3A Assembly protocol, or any other ligation.</p>
 
</td>
 
</td>
Line 40: Line 40:
  
 
===Protocol===  
 
===Protocol===  
''estimated time: 30 minutes active, 2.5 hours incubation''
+
''estimated time: 30 minutes active, 1.5 hours incubation''
 
#Spin down the DNA tubes from the Competent Cell Test Kit/Transformation Efficiency Kit to collect all of the DNA into the bottom of each tube prior to use. A quick spin of 20-30 seconds at 8,000-10,000 rpm will be sufficient. <i>Note:</i> There should be 50 &micro;L of DNA in each tube sent in the Kit.
 
#Spin down the DNA tubes from the Competent Cell Test Kit/Transformation Efficiency Kit to collect all of the DNA into the bottom of each tube prior to use. A quick spin of 20-30 seconds at 8,000-10,000 rpm will be sufficient. <i>Note:</i> There should be 50 &micro;L of DNA in each tube sent in the Kit.
#Thaw competent cells on ice. Label one 2.0ml microcentrifuge tube for each concentration and then pre-chill by placing the tubes on ice.  
+
#Thaw competent cells on ice. Label one 1.5mL microcentrifuge tube for each concentration and then pre-chill by placing the tubes on ice.  
#Pipet 1 &micro;L of DNA into each microcentrifuge tube. For each concentration, use a separate tube.
+
#Pipet 1 &micro;L of DNA into each microcentrifuge tube. For each concentration, use a separate tube. Do triplicates (3 each) of each tube if possible, so you can calculate an average colony yield.
 
#Pipet 50 &micro;L of competent cells into each tube. Flick the tube gently with your finger to mix. Incubate on ice for 30 minutes. Pre-heat waterbath now to 42°C. Otherwise, hot water and an accurate thermometer works, too!
 
#Pipet 50 &micro;L of competent cells into each tube. Flick the tube gently with your finger to mix. Incubate on ice for 30 minutes. Pre-heat waterbath now to 42°C. Otherwise, hot water and an accurate thermometer works, too!
#Heat-shock the cells by placing into the waterbath for 1 minute. Be careful to keep the lids of the tubes above the water level, and keep the ice close by.
+
#Heat-shock the cells by placing into the waterbath for 45 seconds. Be careful to keep the lids of the tubes above the water level, and keep the ice close by.
 
#Immediately transfer the tubes back to ice, and incubate on ice for 5 minutes. This helps the cells recover.
 
#Immediately transfer the tubes back to ice, and incubate on ice for 5 minutes. This helps the cells recover.
#Add 200 &micro;L of SOC media per tube, and incubate at 37°C for 2 hours. Prepare the agar plates during this time: label them, and add sterile glass beads if using beads to spread the mixture.  
+
#Add 950 &micro;L of SOC media per tube, and incubate at 37°C for 1 hours shaking at 250-300rpm. Prepare the agar plates during this time: label them, and add sterile glass beads if using beads to spread the mixture.  
#Pipet 20 &micro;L from each tube onto the appropriate plate, and spread the mixture evenly across the plate. Do triplicates (3 each) of each tube if possible, so you can calculate an average colony yield. Incubate at 37°C overnight or approximately 16 hours. Position the plates so the agar side is facing up, and the lid is facing down.  
+
#Pipet 100 &micro;L from each tube onto the appropriate plate, and spread the mixture evenly across the plate. Incubate at 37°C overnight or approximately 16 hours. Position the plates so the agar side is facing up, and the lid is facing down.  
 
#Count the number of colonies on a light field or a dark background, such as a lab bench. Use the following equation to calculate your competent cell efficiency. If you've done triplicates of each sample, use the average cell colony count in the calculation.
 
#Count the number of colonies on a light field or a dark background, such as a lab bench. Use the following equation to calculate your competent cell efficiency. If you've done triplicates of each sample, use the average cell colony count in the calculation.
 
#*(colonies on plate) / ng of DNA plated x 1000ng/&micro;g
 
#*(colonies on plate) / ng of DNA plated x 1000ng/&micro;g
Line 60: Line 60:
 
{| class="wikitable" style="text-align: center;"
 
{| class="wikitable" style="text-align: center;"
 
|DNA concentration
 
|DNA concentration
|0.5pg/ul
+
|10 pg/&micro;L
|5pg/ul
+
|50 pg/&micro;L
|10pg/ul
+
|100 pg/&micro;L
|20pg/ul
+
|50pg/ul
+
 
|-
 
|-
 
|# of colonies
 
|# of colonies
|10 - 20
 
|120 - 170
 
 
|280 - 360
 
|280 - 360
|480 - 802
 
 
|500 - 1000+  
 
|500 - 1000+  
 +
|
 
|}
 
|}
  
 
''You can [[:File:CompCellsTest_Calculation.xls|download '''Transformation Efficiency Calculation.xls''']] for convenient calculation of the efficiencies.'' ([[User:Mosthege|mosthege]] 03:07, 22 May 2014 (CDT))
 
''You can [[:File:CompCellsTest_Calculation.xls|download '''Transformation Efficiency Calculation.xls''']] for convenient calculation of the efficiencies.'' ([[User:Mosthege|mosthege]] 03:07, 22 May 2014 (CDT))

Revision as of 14:54, 24 April 2017

Competent Cell Test Kit

Before using your competent cells in an experiment, use the Competent Cell Test Kit to test the efficiency of your competent cells!

The kit includes three vials of purified plasmid DNA from BBa_J04450 (RFP construct) in plasmid backbone pSB1C3. Each vial contains DNA at a different concentration: 100 pg/µL, 50 pg/µL, 10 pg/µL. Perform transformations with each of these to determine how efficient your competent cells are.

Note: Transformations performed with ligation products usually do not yield as many colonies because of the low DNA concentration in the ligation mixture. This means that you may see different results doing this test than you will at the end of the 3A Assembly protocol, or any other ligation.

Materials needed

  • 70% ethanol
  • Paper towels
  • Lab marker / Sharpie
  • Container for ice
  • Ice
  • Competent cell aliquot(s)
  • Competent Cell Test Kit
  • Agar plates with chloramphenicol
  • Waterbath (or hot water source and thermometer
  • Incubator
  • SOC media
  • Sterile glass beads or inoculating loop
  • Pipettor
  • Pipette tips


Protocol

estimated time: 30 minutes active, 1.5 hours incubation

  1. Spin down the DNA tubes from the Competent Cell Test Kit/Transformation Efficiency Kit to collect all of the DNA into the bottom of each tube prior to use. A quick spin of 20-30 seconds at 8,000-10,000 rpm will be sufficient. Note: There should be 50 µL of DNA in each tube sent in the Kit.
  2. Thaw competent cells on ice. Label one 1.5mL microcentrifuge tube for each concentration and then pre-chill by placing the tubes on ice.
  3. Pipet 1 µL of DNA into each microcentrifuge tube. For each concentration, use a separate tube. Do triplicates (3 each) of each tube if possible, so you can calculate an average colony yield.
  4. Pipet 50 µL of competent cells into each tube. Flick the tube gently with your finger to mix. Incubate on ice for 30 minutes. Pre-heat waterbath now to 42°C. Otherwise, hot water and an accurate thermometer works, too!
  5. Heat-shock the cells by placing into the waterbath for 45 seconds. Be careful to keep the lids of the tubes above the water level, and keep the ice close by.
  6. Immediately transfer the tubes back to ice, and incubate on ice for 5 minutes. This helps the cells recover.
  7. Add 950 µL of SOC media per tube, and incubate at 37°C for 1 hours shaking at 250-300rpm. Prepare the agar plates during this time: label them, and add sterile glass beads if using beads to spread the mixture.
  8. Pipet 100 µL from each tube onto the appropriate plate, and spread the mixture evenly across the plate. Incubate at 37°C overnight or approximately 16 hours. Position the plates so the agar side is facing up, and the lid is facing down.
  9. Count the number of colonies on a light field or a dark background, such as a lab bench. Use the following equation to calculate your competent cell efficiency. If you've done triplicates of each sample, use the average cell colony count in the calculation.
    • (colonies on plate) / ng of DNA plated x 1000ng/µg
    • Note: The measurement "ng of DNA plated" refers to how much DNA was plated onto each agar plate, not the total amount of DNA used per transformation. You can calculate this number using the following equation:
    • 1 µL x concentration of DNA (refer to vial) x (volume plated / total reaction volume)

Results

Competent cells should have an efficiency of 1.5x10^8 to 6x10^8 cfu/µg DNA, where "cfu" means "colony-forming unit" and is a measurement of cells.

Here are some sample results:

DNA concentration 10 pg/µL 50 pg/µL 100 pg/µL
# of colonies 280 - 360 500 - 1000+

You can download Transformation Efficiency Calculation.xls for convenient calculation of the efficiencies. (mosthege 03:07, 22 May 2014 (CDT))