Difference between revisions of "Part:BBa K1758313"

(Created page with "===Usage and Biology=== <html> <p align="justifiy"> Our sensor for chromium detection consists of ChrB the repressor and the chromate specific promoter ChrP. The promoter is regu...")
 
Line 2: Line 2:
 
<html>
 
<html>
 
<p align="justifiy">
 
<p align="justifiy">
Our sensor for chromium detection consists of ChrB the repressor and the chromate specific promoter ChrP. The promoter is regulated by the ChrP used for<i>in vivo</i> characterization.</figcaption>
+
Our sensor for chromium detection consists of <i>chrB</i> the repressor and the chromate specific promoter <i>chrP</i>. The promoter is regulated by the <i>chrP</i> used for<i>in vivo</i> characterization.</figcaption>
 
</figure>, which binds Cr-ions. Behind the promoter is a sfGFP for detection of a fluorescence signal.</p>
 
</figure>, which binds Cr-ions. Behind the promoter is a sfGFP for detection of a fluorescence signal.</p>
 
<i>In vivo</i> we could show that the addition of different concentrations of chromium have different effects to transcription of sfGFP.</p>
 
<i>In vivo</i> we could show that the addition of different concentrations of chromium have different effects to transcription of sfGFP.</p>

Revision as of 02:57, 19 September 2015

Usage and Biology

Our sensor for chromium detection consists of chrB the repressor and the chromate specific promoter chrP. The promoter is regulated by the chrP used forin vivo characterization. , which binds Cr-ions. Behind the promoter is a sfGFP for detection of a fluorescence signal.

In vivo we could show that the addition of different concentrations of chromium have different effects to transcription of sfGFP.

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    INCOMPATIBLE WITH RFC[12]
    Illegal NheI site found at 55
    Illegal NheI site found at 966
    Illegal NheI site found at 989
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal BglII site found at 1144
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal AgeI site found at 124
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal SapI.rc site found at 1237


Results

Our sensors were cultivated in the BioLector. Due to the accuracy of this device we could measure our sample in duplicates.

Adjusting the detection limit
Time course of the induction of a chromium biosensor with sfGFP for different chromium concentrations in vivo. The data are measured with BioLector and normalized on OD600. Error bars represent the standard deviation of two biological replicates.
Adjusting the detection limit
Fluorescence levels at three different stages of cultivation. Shown are levels after 60 minutes, 150 minutes and 650 minutes. Error bars represent the standard deviation of three biological replicates.

Our data lead to the conclusion that in a cell based system it is possible to detect chromium. In contrast to our expectations with higher chromium concentrations we got lower fluorescence levels. These observations needed further investigation.