Difference between revisions of "Part:BBa K1045013:Experience"
(→Plate reader data) |
(→Microscope data) |
||
Line 16: | Line 16: | ||
[[File:-DarR.jpg|420px|thumb|'''Fig. 1.''': ''Top'': ''E. coli'' transformed with a control plasmid encoding [[Part:BBa_K1045013|BBa_K1045013]]. ''Bottom'': ''E. coli'' transformed with a plasmid harboring the DarR reporter system [[Part:BBa_K1045017|BBa_K1045017]]. Cells of both strains were cultured without c-di-AMP and analyzed by fluorescence microscopy. Both pictures represent merges of a bright field image and a GFP fluorescence image. The exposure time used to record GFP fluorescence was in both cases 2 seconds. [[File:+DarR.jpg|420px]]|center]] | [[File:-DarR.jpg|420px|thumb|'''Fig. 1.''': ''Top'': ''E. coli'' transformed with a control plasmid encoding [[Part:BBa_K1045013|BBa_K1045013]]. ''Bottom'': ''E. coli'' transformed with a plasmid harboring the DarR reporter system [[Part:BBa_K1045017|BBa_K1045017]]. Cells of both strains were cultured without c-di-AMP and analyzed by fluorescence microscopy. Both pictures represent merges of a bright field image and a GFP fluorescence image. The exposure time used to record GFP fluorescence was in both cases 2 seconds. [[File:+DarR.jpg|420px]]|center]] | ||
+ | |||
+ | '''Experimental details''': | ||
+ | ''E. coli'' cells were grown in LB medium until log phase. A culture aliquot was prepared on slides covered with 1 % agarose (in water) and the cells observed under the fluorescence microscope. For all images, the same exposure time was used. Microscope: Axioskop 40 FL fluorescence microscope; Camera: digital camera AxioCam MRm; Software for image processing: AxioVision Rel version 4.8 (Carl Zeiss, Göttingen, Germany); Objective: Neofluar series objective (×100 primary magnification); Filter set: eGFP HC-Filterset (band-pass [BP] 472/30, FT 495, and long-pass [LP] 520/35; AHF Analysentechnik, Tübingen, Germany) for GFP detection. | ||
== Plate reader data == | == Plate reader data == |
Revision as of 14:20, 26 October 2013
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K1045013
This composite part is functional as indicated by the characterization experiments of our DarR reporter system BBa_K1045017. For this, we used BBa_K1045013 as a control plasmid. Without DarR, GFP was expressed. With DarR (but without c-di-AMP!), GFP expression was turned off. These characterization experiments are described below:
Microscope data
For characterization, E. coli BL21 was transformed either with BBa_K1045017 or with BBa_K1045013 as a control. Both strains were grown in the abscence of c-di-AMP and subjected to fluorescence microscopy.
In BBa_K1045013, gfp is placed downstream of a strong promoter and the DarR operator. This vector does not encode for DarR. The strong fluorescence of the cells transformed with BBa_K1045013 (Fig. 1 top) indicated that GFP was expressed. However, when transformed with BBa_K1045017 (Fig. 1 bottom), the cells showed almost no fluorescence. In contrast to BBa_K1045013, BBa_K1045017 encodes for DarR. The low fluorescence suggested that DarR was expressed and active as a repressor down-regulating gfp transcription. Moreover, the results suggested that the control construct BBa_K1045013 was functional as it allowed GFP expression and regulation by DarR.
Experimental details: E. coli cells were grown in LB medium until log phase. A culture aliquot was prepared on slides covered with 1 % agarose (in water) and the cells observed under the fluorescence microscope. For all images, the same exposure time was used. Microscope: Axioskop 40 FL fluorescence microscope; Camera: digital camera AxioCam MRm; Software for image processing: AxioVision Rel version 4.8 (Carl Zeiss, Göttingen, Germany); Objective: Neofluar series objective (×100 primary magnification); Filter set: eGFP HC-Filterset (band-pass [BP] 472/30, FT 495, and long-pass [LP] 520/35; AHF Analysentechnik, Tübingen, Germany) for GFP detection.
Plate reader data
We furthermore produced quantitative data characterizing the growth and the fluorescence over time of the BL21 E. colis we transformed with the DarR reporter system construct BBa_K1045017. As a control, we used E. coli cells harboring the BBa_K1045013 plasmid. This plasmid carries only the GFP expression unit with a strong promoter and the DarR operator. It does not encode for DarR.
Plate reader experiments were performed to quantify the strength of the DarR construct in E. coli. In these experiments, a dilution series of c-di-AMP (0, 50, 100, 150, 300, 500 and 1000 nmol c-di-AMP) was used to test the reaction of the DarR reporter system to the nucleotide. Two biological replicates were done. For each biological replicate, three technical replicates were analyzed. The graphs below show the mean value of the technical replicates of one biological replicate. The error bars indicate the standard deviation.
Fig. 2 shows the growth curves recorded via the optical density (OD) at the wavelength 600 nm. The GFP fluorescence was measured at 509 nm over the time, as well. Since the fluorescence depends on the growth of the E. coli cells, the GFP fluorescence was normalized to the OD at 600 nm for each time point (Fig. 3).
Experimental setup: total time 21 h; 15 min measurement interval; 37°C, medium shaking; 96-well titer plate; Synergy Mx Monochromator-Based Multi-Mode Microplate Reader; Gen5 V2.01
As in the microscope experiments described above, the expression of the reporter was prevented (even without c-di-AMP), when DarR was encoded in the vector. This data suggested that DarR was expressed and active. In addition, the composite part BBa_K1045013 was functional as it allowed GFP expression that was shut down by DarR.
User Reviews