Difference between revisions of "Part:BBa K1051258"

Line 26: Line 26:
 
The test results of BBa_K1051258 in chip. A,LB medium,O minuts; B, IPTG medium,9minutes; C,IPTG medium, 15 minutes
 
The test results of BBa_K1051258 in chip. A,LB medium,O minuts; B, IPTG medium,9minutes; C,IPTG medium, 15 minutes
 
<br />
 
<br />
 +
https://static.igem.org/mediawiki/parts/8/80/Average-fluorescence-intensity-of-K1051258-measurement.jpg
 +
The average fluorescence intensity of K1051258 when added IPTG after specific time.
  
 
<h3>Sequence and Features</h3>
 
<h3>Sequence and Features</h3>

Revision as of 21:22, 27 September 2013

Construct the measurement pathway of K1051207.

Purpose

Construct the measurement pathway of K1051207.

Principle

SsrA degradation tag. In E. coli, the adaptor SspB tethers ssrAtagged substrates to the ClpXP protease, causing a modest increase in their rate of degradation. Which means, a variation of the WT SsrA tag sequence will accelerate the degradation of proteins when fused to their C-terminal. Thus the degradation rates are dependent on concentration of proteases and binding mediators. In order to fuse degradation tags freely on the C-terminal of protein, we add TAATAA to the tail of M0051 to construnt this K1051207.
We constructed the measurement pathway K1051258(contains J04500, K1051000 and K1051207) to test the rates of degradation of tagged proteins. J04450 was used as positive control because of the same promoter and fluorescent protein.

Measurement

Curve_ecdeg.png The growth curve of E. coli. Degladder.jpg From right to left, the negative control,BBa_K1051257, BBa_K1051258, BBa_K1051259, J04450 as Positive Control. As the pictures showed, the lights of RFP within three degradation tags are decreasing.

Flo2.jpg The test results of BBa_K1051258. A:No exciting lights; B. Powerful exciting lights; C. Weak exciting lights. In picture, there are only obvious lights in the picture B, indicated the degradation rates are working Degmicro.jpg The test results of BBa_K1051258 in chip. A,LB medium,O minuts; B, IPTG medium,9minutes; C,IPTG medium, 15 minutes
Average-fluorescence-intensity-of-K1051258-measurement.jpg The average fluorescence intensity of K1051258 when added IPTG after specific time.

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal AgeI site found at 781
    Illegal AgeI site found at 893
  • 1000
    COMPATIBLE WITH RFC[1000]



References

[1]McGinness, Baker, Sauer. 2006. Mol. Cell. 22:701.
[2]Flynn et al 2003. Mol. Cell. 11: 671. Flynn et al. 2001. PNAS 98(19): 10584. Anderson et al 1998. App. Env. Microbiol. 64(6):2240