− | We calculated the amount of isoprene by [http://2011.igem.org/Team:Tokyo_Tech/Projects/making-rain/GC-Assay#AP calibration date we obtained]. | + | We calculated the amount of isoprene by [http://2011.igem.org/Team:Tokyo_Tech/Projects/making-rain/GC-Assay#AP calibration date we obtained]. X represents the area and Y represents the amount of isoprene [mg], the calibration curve is described by the equation,<br> '''Y = 10<sup>-7.9</sup> × X<sup>0.89</sup>.'''<br> |
According to the calibration curve, we detected 4.1×10<sup>-5</sup> mg/L isoprene produced by ''E. coli'' BL21 (DE3) introduced ispS, while negative control (PlacIQ) produced one eighth of our new ''E. coli''. | According to the calibration curve, we detected 4.1×10<sup>-5</sup> mg/L isoprene produced by ''E. coli'' BL21 (DE3) introduced ispS, while negative control (PlacIQ) produced one eighth of our new ''E. coli''. | ||
Revision as of 11:58, 28 October 2011
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K649303
We confirmed that E. coli introduced ispS synthesize isoprene.
We calculated the amount of isoprene by [http://2011.igem.org/Team:Tokyo_Tech/Projects/making-rain/GC-Assay#AP calibration date we obtained]. X represents the area and Y represents the amount of isoprene [mg], the calibration curve is described by the equation,
Y = 10-7.9 × X0.89.
According to the calibration curve, we detected 4.1×10-5 mg/L isoprene produced by E. coli BL21 (DE3) introduced ispS, while negative control (PlacIQ) produced one eighth of our new E. coli.
To measure the amount of isoprene produced by our E. coli, we used electron-ionization Gas Chromatography-Mass Spectrometry equipment (GC-MS, QP-2010, SHIMADZU, Japan). Analytes were separated by a nonpolar column (Rtx-1MS: Length 30 m, ID 0.25 mm film thickness 0.5 µm, USA) working in a constant flow mode (2.99 mL min-1). The temperature program was chosen as follows: 40℃ for 7 min, increase to 280℃ at rate of 10℃ min-1, 280℃ for 5 min. The mass spectrometer worked in SIM mode, m/z 67. The retention time of isoprene is very short (about 1.06-1.10 min).
For more information, see [http://2011.igem.org/Team:Tokyo_Tech/Projects/making-rain/index.htm our work in Tokyo_Tech 2011 wiki].
User Reviews