Difference between revisions of "Part:BBa K5439003"

Line 12: Line 12:
 
=Usage and Biology=
 
=Usage and Biology=
 
<div style="text-align:justify;">
 
<div style="text-align:justify;">
 +
 +
Rifampicin (RAMP) is an antibiotic widely used in the treatment of severe bacterial infections such as tuberculosis, meningitis, leprosy, and HIV-associated infections. RAMP residues contaminate water sources, primarily through human excretions (urine and feces) and waste generated by the pharmaceutical industry and animal husbandry. Due to its high solubility and environmental stability, RAMP is not fully removed by wastewater treatment plants, contributing to the development of antibiotic-resistant bacteria (ARB) 3 .
 +
 +
=Selecting Fluorescent Proteins=
 +
<div style="text-align:justify;">
 +
 +
FRET (Fluorescence Resonance Energy Transfer) is often used in the design of biosensors as it allows for the specific and sensitive detection of biomolecules in a highly specific manner with high sensitivity, without the need to induce a change in the biomolecule. The fluorescence of the acceptor molecule is activated only when both the donor fluorophore and the acceptor molecule are in proximity. This means that any changes in their surrounding environment that affect the distance between them will also impact the fluorescence of the molecule. This mechanism of action enables the detection of changes in the environment, even if they are subtle, without the need to genetically modify the molecule. FRET is a non-radiative process, which means it does not produce any ionizing radiation. This makes this type of biosensor safer to use and handle compared to others. Additionally, they are very sensitive and versatile biosensors, allowing them to detect the presence of a wide variety of biomolecules, as well as changes in the environment. They can detect protein-protein interactions, monitor changes in pH, measure enzyme activity, among others 2 .
 +
 +
=Characterization=
  
 
With the DNA fragments purified from an agarose gel, we performed ligation at a molar ratio of 1:5 for vector and insert, as shown in <b>Figure 3</b>. The total vector concentration was 100 nanograms, whereas the reaction volume was 20 µL. Next, <b>Table 2</b> displays the protocol followed for the reaction.
 
With the DNA fragments purified from an agarose gel, we performed ligation at a molar ratio of 1:5 for vector and insert, as shown in <b>Figure 3</b>. The total vector concentration was 100 nanograms, whereas the reaction volume was 20 µL. Next, <b>Table 2</b> displays the protocol followed for the reaction.

Revision as of 23:28, 1 October 2024


FRET-based system for the detection of rifampicin

FRET-based sensor system for the detection of rifampicin that consists of rifampicin monooxygenase (K4447003), an enzyme that catalyzes the hydroxylation of rifampicin, flanked by two fluorescent proteins: ECFP (BBa_K1159302) as energy donor and mVenus (BBa_K1907000) as an energy acceptor.

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal XhoI site found at 1913
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal BsaI.rc site found at 2562

Usage and Biology

Rifampicin (RAMP) is an antibiotic widely used in the treatment of severe bacterial infections such as tuberculosis, meningitis, leprosy, and HIV-associated infections. RAMP residues contaminate water sources, primarily through human excretions (urine and feces) and waste generated by the pharmaceutical industry and animal husbandry. Due to its high solubility and environmental stability, RAMP is not fully removed by wastewater treatment plants, contributing to the development of antibiotic-resistant bacteria (ARB) 3 .

Selecting Fluorescent Proteins

FRET (Fluorescence Resonance Energy Transfer) is often used in the design of biosensors as it allows for the specific and sensitive detection of biomolecules in a highly specific manner with high sensitivity, without the need to induce a change in the biomolecule. The fluorescence of the acceptor molecule is activated only when both the donor fluorophore and the acceptor molecule are in proximity. This means that any changes in their surrounding environment that affect the distance between them will also impact the fluorescence of the molecule. This mechanism of action enables the detection of changes in the environment, even if they are subtle, without the need to genetically modify the molecule. FRET is a non-radiative process, which means it does not produce any ionizing radiation. This makes this type of biosensor safer to use and handle compared to others. Additionally, they are very sensitive and versatile biosensors, allowing them to detect the presence of a wide variety of biomolecules, as well as changes in the environment. They can detect protein-protein interactions, monitor changes in pH, measure enzyme activity, among others 2 .

Characterization

With the DNA fragments purified from an agarose gel, we performed ligation at a molar ratio of 1:5 for vector and insert, as shown in Figure 3. The total vector concentration was 100 nanograms, whereas the reaction volume was 20 µL. Next, Table 2 displays the protocol followed for the reaction.

Table 2. DNA ligation conditions.
Reactive Quantity
T4 DNA Ligase Buffer (10X) 2 µL
Vector DNA 100 ng
Insert DNA 773.5 ng
Nuclease-free water To 20 µL
T4 DNA Ligase 1.5 µL