Difference between revisions of "Part:BBa K176026"
(→MEASUREMENT) |
(→data) |
||
Line 29: | Line 29: | ||
===data=== | ===data=== | ||
+ | {|- | ||
+ | |align = "center"| | ||
+ | <br /> | ||
+ | <font size = "5">K176026?</font> | ||
{| {{table}} | {| {{table}} | ||
{|class="sortable" style="border:3px solid black; width: 70%" align="center" | {|class="sortable" style="border:3px solid black; width: 70%" align="center" |
Revision as of 18:37, 20 October 2009
TetR repressible AHL->GFP Receiver (Very High LuxR): pCon 0.70->luxR+pLux/Tet->GFP
AHL -> GFP
TetR repressible
Very high LuxR level
K176028 with GFP.
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12INCOMPATIBLE WITH RFC[12]Illegal NheI site found at 7
Illegal NheI site found at 30 - 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000INCOMPATIBLE WITH RFC[1000]Illegal BsaI.rc site found at 985
Illegal BsaI.rc site found at 1729
MEASUREMENT
We mesured the hybrid promoter's response to AHL concentration through different devices. INPUT: AHL DEVICE: TetR repressible AHL->GFP Receiver: K176026 ( pCon 0.70->luxR+pLux/Tet->GFP ); K176126 ( pCon 0.36->luxR+pLux/Tet->GFP ); K176128 ( pCon 0.15->luxR+pLux/Tet->GFP ); K176130 (pCon 0.04->luxR+pLux/Tet->GFP ); OUTPUT: GFP
data
For the details of the definition of ST.FLU and the unit ustc_st1, please click here. plotprotocolAHLHybrid promoter:BBa_K176026, BBa_K176126, BBa_K176128, BBa_K176130 1. Streak a plate of the strain which contain one of the parts listed in pSB1A3 . 2. Inoculate two 3ml cultures of supplemented M9 Medium and antibiotic(Ampicillin 0.1mg/ml) with single colony from the plate. 3. Cultures were grown in test tubes(BIO BASIC INC.12ml Polypropylene Round-bottom Culture Tubes With Graduations And Dual Cap Cat.No:TD444) for 16hrs at 37℃ with shaking at 200rpm. 4. Cultures were diluted 1:1000 to tubes of 3ml fresh medium and grown for 4.5hrs. 5. Stock concentration of the cognate AHL, 3-oxohexanoyl-homoserine is diluted and added to different tubes to yield different final concentrations (1E-5,1E-7,1E-8,1E-9,1E-10M).To ensure the same response time , the AHL should be added with a time interval of 2mins between tubes, so do the measurements procedure. 6. Measure the fluorescence(SHIMDZU SPECTROFLUOROPHOTOMETER RF-5301PC, 250ul quartz cell path length 10mm,501 nm excitation,514 nm emission,1.5nm slit width) and absorbance ((HITACHI UV-VIS spectrophotometer U-2810 ,200ul quartz cell path length 10mm,600nm,1.5 nm slit width) for the first time 30 minutes after adding AHL. Repeat measurement every 30 mins in the next 4hrs.
|