FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. This part is the expression cassette for BBa_K4438107, with BBa_J64997 upstream and BBa_K731721 downstream, along with the spacer sequences BBa_K3831027(at 5’ end) and BBa_K4438136(at 3’end). FASTmiR-146a-D3_s, after transcription, binds to miR-146a, the transcription product of BBa_K4438501. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.
+
FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. This part is the expression cassette for <partinfo>BBa_K4438107</partinfo>, with <partinfo>BBa_J64997</partinfo> upstream and <partinfo>BBa_K731721</partinfo> downstream, along with the spacer sequences <partinfo>BBa_K3831027</partinfo>(at 5’ end) and <partinfo>BBa_K4438136</partinfo>(at 3’end). FASTmiR-146a-D3_s, after transcription, binds to miR-146a, the transcription product of <partinfo>BBa_K4438151<partinfo>. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.
  
  
 
===Usage and Biology===
 
===Usage and Biology===
This part can be used for the detection of miR-146a, which proves to be a biomarker for many diseases. A promoter sequence added in the beginning enhances its usage in both in-vivo and in-vitro conditions. The ON and OFF structure for the sensor was generated as given:
+
This part can be used for the detection of miR-146a, which proves to be a biomarker for many diseases. A promoter sequence added in the beginning enhances its usage in both in-vivo and in-vitro conditions. The OFF(A) and ON(B) structure for the sensor was generated as given:
 
+
  
 +
[[File:T--IISER-Tirupati_India--miRNA_146_3.png]]
  
 
<!-- -->
 
<!-- -->

Revision as of 09:45, 12 October 2022

FASTmiR-146a-D3_s

FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. This part is the expression cassette for BBa_K4438107, with BBa_J64997 upstream and BBa_K731721 downstream, along with the spacer sequences BBa_K3831027(at 5’ end) and BBa_K4438136(at 3’end). FASTmiR-146a-D3_s, after transcription, binds to miR-146a, the transcription product of No part name specified with partinfo tag.


Notes

The split position of the complementary sequence in the sensor is CTGAAGAACT….GAATTTCAGAGG

References