Difference between revisions of "Part:BBa K4245107:Design"
Line 21: | Line 21: | ||
<br> | <br> | ||
Jonstrup, S. P., Koch, J., & Kjems, J. (2006). A microRNA detection system based on padlock probes and rolling circle amplification. RNA, 12(9), 1747–1752. https://doi.org/10.1261/rna.110706 | Jonstrup, S. P., Koch, J., & Kjems, J. (2006). A microRNA detection system based on padlock probes and rolling circle amplification. RNA, 12(9), 1747–1752. https://doi.org/10.1261/rna.110706 | ||
+ | |||
+ | |||
Liu, H., Li, L., Duan, L., Wang, X., Xie, Y., Tong, L., Wang, Q., & Tang, B. (2013). High specific and ultrasensitive isothermal detection of microRNA by padlock probe-based exponential rolling circle amplification. Analytical Chemistry, 85(16), 7941–7947. https://doi.org/10.1021/ac401715k | Liu, H., Li, L., Duan, L., Wang, X., Xie, Y., Tong, L., Wang, Q., & Tang, B. (2013). High specific and ultrasensitive isothermal detection of microRNA by padlock probe-based exponential rolling circle amplification. Analytical Chemistry, 85(16), 7941–7947. https://doi.org/10.1021/ac401715k |
Revision as of 16:28, 11 October 2022
5
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]
Design Notes
For the padlock probe (PLP) design, part of the reverse complement of the miRNA makes up each end of the padlock probe. To determine where the reverse complement is split properly, we determined the annealing temperatures of each arm through SnapGene. To allow successful hybridization and maximize the binding efficiency of the miRNA and the padlock arms, the arms need to have the same annealing temperature. Furthermore, we added a phosphate group modification to the 5’ end of the padlock sequence to allow ligation by SplintR ligase (Jonstrup et al., 2006).
Additionally, the alignment of the 5’ and 3’ ends is essential to determine where each part of the padlock and its arms matches up to the target miRNA (Liu et al., 2013). The miRNA strand hybridizes antiparallel to the padlock arms (see Fig. 1) Therefore, the 5’ end of the miRNA will end up overlapping the 5’ PLP arm, and the 3’ end of the miRNA will end up overlapping the 3’ PLP arm (Liu et al., 2013).
Source
References
Jonstrup, S. P., Koch, J., & Kjems, J. (2006). A microRNA detection system based on padlock probes and rolling circle amplification. RNA, 12(9), 1747–1752. https://doi.org/10.1261/rna.110706
Liu, H., Li, L., Duan, L., Wang, X., Xie, Y., Tong, L., Wang, Q., & Tang, B. (2013). High specific and ultrasensitive isothermal detection of microRNA by padlock probe-based exponential rolling circle amplification. Analytical Chemistry, 85(16), 7941–7947. https://doi.org/10.1021/ac401715k