Difference between revisions of "Part:BBa J428112:Experience"
(→Characterization of BBa_J428112) |
Manasvigupta (Talk | contribs) |
||
Line 1: | Line 1: | ||
− | |||
− | |||
− | |||
− | |||
− | |||
===Characterization of BBa_J428112=== | ===Characterization of BBa_J428112=== | ||
Lambert iGEM 2022 transformed the InterLab Experiment 1 Test Device 1 (BBa_J428112) into two different strains of E. coli (BL21 and DH5-alpha) to characterize the differences in fluorescence. BL21 is used for protein expression, whereas DH5-alpha is utilized for plasmid transformation. Therefore, we expect the test device transformed into the BL21 cells to produce more fluorescence than those transformed into DH5-alpha. Lambert iGEM quantified the fluorescence at a 0 and 5 hour time point to determine the changes in fluorescence over a longer period of time. We used the iGEM InterLab Experiment 1 Protocol with minor alterations to characterize this part. The InterLab study instructs to quantify the sample at a 0 hour and 6 hour time mark. To better align with members’ schedules, we quantified fluorescence at a 0 hour and 5 hour time mark. Additionally, rather than quantifying 8 different test devices, we quantified only one in both BL21 and DH5-alpha to focus on the variance in fluorescence in different cell strains. | Lambert iGEM 2022 transformed the InterLab Experiment 1 Test Device 1 (BBa_J428112) into two different strains of E. coli (BL21 and DH5-alpha) to characterize the differences in fluorescence. BL21 is used for protein expression, whereas DH5-alpha is utilized for plasmid transformation. Therefore, we expect the test device transformed into the BL21 cells to produce more fluorescence than those transformed into DH5-alpha. Lambert iGEM quantified the fluorescence at a 0 and 5 hour time point to determine the changes in fluorescence over a longer period of time. We used the iGEM InterLab Experiment 1 Protocol with minor alterations to characterize this part. The InterLab study instructs to quantify the sample at a 0 hour and 6 hour time mark. To better align with members’ schedules, we quantified fluorescence at a 0 hour and 5 hour time mark. Additionally, rather than quantifying 8 different test devices, we quantified only one in both BL21 and DH5-alpha to focus on the variance in fluorescence in different cell strains. |
Revision as of 20:29, 6 October 2022
Characterization of BBa_J428112
Lambert iGEM 2022 transformed the InterLab Experiment 1 Test Device 1 (BBa_J428112) into two different strains of E. coli (BL21 and DH5-alpha) to characterize the differences in fluorescence. BL21 is used for protein expression, whereas DH5-alpha is utilized for plasmid transformation. Therefore, we expect the test device transformed into the BL21 cells to produce more fluorescence than those transformed into DH5-alpha. Lambert iGEM quantified the fluorescence at a 0 and 5 hour time point to determine the changes in fluorescence over a longer period of time. We used the iGEM InterLab Experiment 1 Protocol with minor alterations to characterize this part. The InterLab study instructs to quantify the sample at a 0 hour and 6 hour time mark. To better align with members’ schedules, we quantified fluorescence at a 0 hour and 5 hour time mark. Additionally, rather than quantifying 8 different test devices, we quantified only one in both BL21 and DH5-alpha to focus on the variance in fluorescence in different cell strains.
User Reviews
UNIQ6f08aafec284ce51-partinfo-00000000-QINU UNIQ6f08aafec284ce51-partinfo-00000001-QINU