Difference between revisions of "Part:BBa K4441006"

 
Line 3: Line 3:
 
<partinfo>BBa_K4441006 short</partinfo>
 
<partinfo>BBa_K4441006 short</partinfo>
  
24 41 18 55.71 -5.42 -4.27 50 TCCACAGAGACCTCAAGA
+
Sequence used in wetlab experiments: TTCTCTGTAGCTAGACCAAAATCACTCCACAGAGACCTCAAGA taken from [1]
  
<!-- Add more about the biology of this part here
 
 
===Usage and Biology===
 
===Usage and Biology===
 +
This is the sequence for the Forward Inner Primer. The FIP consists of a F2 region at the 3'end and a F1c region at the 5'end [2]. The F2 region is complementary to the F2c region of the template sequence. The F1c region is identical to the F1c region of the template sequence [2]. This FIP primer is part of the primer set that detects the BRAF V600E:
 +
TTACTTACACGCCAAGTCAATCATCCACAGAGACCTCAAGAGTAATAATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGAGAAATCTCGATGGA
 +
GTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGCACCAGAAGTCATCAGAATGCAAGATAAAAATCCATACAGCTTTCAGTCAGATGTATATGCATTTGGAATT
 +
GTTCTGTATGAATTGATGACTGGACAGTTACCTTATTCAAACATCAACAACAGGGACCAG
 +
 +
====Dilutions====
 +
 +
Storage Primer Concentration: 100 μM
 +
 +
10X Concentration (Stock): 16 μM
 +
 +
Volume of 10X primer mix: 10 μL
 +
 +
1X Concentration (Final):1.6 μM
 +
 +
Volume of storage primer needed: 1.6 μL
 +
 +
Mixed with F3, B3, BIP, LF and LB for a total of 4.4 μL -- Final primer mix
 +
1 μL of final primer mix is used in the LAMP reaction mix. For more information, visit https://2022.igem.org/Team:Washington
 +
 +
====Alternative Sequence====
 +
As this set of primer failed to produce a positive result, we used NEB LAMP Primer Design Tool (https://lamp.neb.com/#!/) to generate an alternative set of primers. Unfortunately, due to time and budgetary constraints, these primers have not been ordered and experimented with yet.
 +
 +
Sequence: TTCTCTGTAGCTAGACCAAAATCACTCCACAGAGACCTCAAGA
 +
 +
len: 43
 +
 +
==Citations==
 +
1. Papadakis, G., Pantazis, A. K., Fikas, N., Chatziioannidou, S., Tsiakalou, V., Michaelidou, K., ... & Gizeli, E. (2022). Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples. Scientific reports, 12(1), 1-15.
 +
 +
2. Loop mediated isothermal amplification - technote. (n.d.). Retrieved October 11, 2022, from http://www.premierbiosoft.com/tech_notes/Loop-Mediated-Isothermal-Amplification.html
  
 
<!-- -->
 
<!-- -->

Revision as of 05:09, 12 October 2022


BRAF V600E FIP

Sequence used in wetlab experiments: TTCTCTGTAGCTAGACCAAAATCACTCCACAGAGACCTCAAGA taken from [1]

Usage and Biology

This is the sequence for the Forward Inner Primer. The FIP consists of a F2 region at the 3'end and a F1c region at the 5'end [2]. The F2 region is complementary to the F2c region of the template sequence. The F1c region is identical to the F1c region of the template sequence [2]. This FIP primer is part of the primer set that detects the BRAF V600E: TTACTTACACGCCAAGTCAATCATCCACAGAGACCTCAAGAGTAATAATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGAGAAATCTCGATGGA GTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGCACCAGAAGTCATCAGAATGCAAGATAAAAATCCATACAGCTTTCAGTCAGATGTATATGCATTTGGAATT GTTCTGTATGAATTGATGACTGGACAGTTACCTTATTCAAACATCAACAACAGGGACCAG

Dilutions

Storage Primer Concentration: 100 μM

10X Concentration (Stock): 16 μM

Volume of 10X primer mix: 10 μL

1X Concentration (Final):1.6 μM

Volume of storage primer needed: 1.6 μL

Mixed with F3, B3, BIP, LF and LB for a total of 4.4 μL -- Final primer mix 1 μL of final primer mix is used in the LAMP reaction mix. For more information, visit https://2022.igem.org/Team:Washington

Alternative Sequence

As this set of primer failed to produce a positive result, we used NEB LAMP Primer Design Tool (https://lamp.neb.com/#!/) to generate an alternative set of primers. Unfortunately, due to time and budgetary constraints, these primers have not been ordered and experimented with yet.

Sequence: TTCTCTGTAGCTAGACCAAAATCACTCCACAGAGACCTCAAGA

len: 43

Citations

1. Papadakis, G., Pantazis, A. K., Fikas, N., Chatziioannidou, S., Tsiakalou, V., Michaelidou, K., ... & Gizeli, E. (2022). Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples. Scientific reports, 12(1), 1-15.

2. Loop mediated isothermal amplification - technote. (n.d.). Retrieved October 11, 2022, from http://www.premierbiosoft.com/tech_notes/Loop-Mediated-Isothermal-Amplification.html

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal BsaI.rc site found at 32