===Experiment1:Toggle Switch Verification=== | ===Experiment1:Toggle Switch Verification=== | ||
+ | We incubated the guards overnight for 12-16h, and then split the experimental material in the ultra-clean bench: five wells of a 96-well plate were poured with 200ul of bacterial solution, followed by 1mM of AIP, and 1ul each of diluted 10^7, 10^8 and 10^9 AIP into the first four wells, leaving a control of the original bacterial solution without AIP. | ||
− | + | Then we put the partitioned experimental material into the microplate reader to detect the fluorescence intensity of mCherry and record the experimental data | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | |||
+ | ===Experiment 2: Vertification of AIP generation=== | ||
− | + | After collecting the standard experimental data, we filtered the 12h culture of the deceiver and mixed the remaining culture with an equal amount of the guard's bacterial solution. 200ul of the culture was placed in a 96-well plate and the mCherry was measured under the microplate reader. | |
− | After collecting the standard experimental data, we filtered the 12h culture of the deceiver and mixed the remaining culture with an equal amount of the guard's bacterial solution. 200ul of the culture was placed in a 96-well plate and the | + | |
==result== | ==result== | ||
Line 32: | Line 26: | ||
When a certain amount of exogenous AIP was applied to the bacterial fluid, red fluorescence(mCherry) was observed under the microscope. After a period of time, red fluorescence disappeared, and green fluorescence was observed under the microscope. | When a certain amount of exogenous AIP was applied to the bacterial fluid, red fluorescence(mCherry) was observed under the microscope. After a period of time, red fluorescence disappeared, and green fluorescence was observed under the microscope. | ||
− | [[File: | + | [[File:|500px|thumb|center|red fluorescence(mCherry) was observed under the microscope]] |
===experiment2=== | ===experiment2=== |
Revision as of 12:28, 21 October 2021
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Experiments of BBa_K3805138
For the synthesis of AIP by agrB-D and the verification of toggle switch functionality using AIP, we also carried out the related experiments
Experiment1:Toggle Switch Verification
We incubated the guards overnight for 12-16h, and then split the experimental material in the ultra-clean bench: five wells of a 96-well plate were poured with 200ul of bacterial solution, followed by 1mM of AIP, and 1ul each of diluted 10^7, 10^8 and 10^9 AIP into the first four wells, leaving a control of the original bacterial solution without AIP.
Then we put the partitioned experimental material into the microplate reader to detect the fluorescence intensity of mCherry and record the experimental data
Experiment 2: Vertification of AIP generation
After collecting the standard experimental data, we filtered the 12h culture of the deceiver and mixed the remaining culture with an equal amount of the guard's bacterial solution. 200ul of the culture was placed in a 96-well plate and the mCherry was measured under the microplate reader.
result
experiment1
When a certain amount of exogenous AIP was applied to the bacterial fluid, red fluorescence(mCherry) was observed under the microscope. After a period of time, red fluorescence disappeared, and green fluorescence was observed under the microscope.
[[File:|500px|thumb|center|red fluorescence(mCherry) was observed under the microscope]]
experiment2
After a period of testing, we finally got our experimental results